9.1 Technical data
General data
Material 316L corresponds to 1.4404 or 1.4435
Materials, wetted parts
- Process fitting - Thread
316L
- Process fitting - Flange
316L
- Process seal
Klingersil C-4400
- Seal (vibrating element)
CR, CSM
- Tuning fork
316L
- Suspension cable
PUR
Materials, non-wetted parts
- Housing
Plastic PBT (Polyester), Alu die-casting pow-
der-coated, 316L
- Seal ring between housing and
housing cover
NBR (stainless steel housing), silicone (Alu/
plastic housing)
- Ground terminal
316L
Weights
- with plastic housing
1500 g (53 oz)
- with Aluminium housing
1950 g (69 oz)
- with stainless steel housing
2300 g (81 oz)
- Suspension cable
165 g/m (1.8 oz/ft)
Max. permissible tensile load
3000 N (675 lbs)
Sensor length
0.3 … 80 m (1 … 262 ft)
Output variable
Output
floating transistor output, overload and perma-
nently shortcircuit proof
Load current
max. 400 mA
Turn-on voltage
max. 55 V DC
Blocking current
<100 µA
Modes (adjustable)
min./max.
Integration time
- when immersed
approx. 0.5 s
- when laid bare
approx. 1 s
Supplement
VEGAVIB 66 - with transistor output
29
29291
-EN
-060508
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)