7 setup with pactware, 1 connect the pc with vegaconnect 3, 7 s etup with pactware – VEGA VEGABAR 74 4 … 20 mA_HART User Manual
Page 21
7 S
etup with PACTware™
7
.1 Connect the PC with VEGACONNECT 3
~
=
2
3
1
4
Power supply
VEGACONNECT 3
PACTware /
TM
Fig. 8: Connecting the PC to the signal cable
1
RS232 connection (with VEGACONNECT 3) or USB connection (with
VEGACONNECT 4)
2
VEGABAR 74
3
HART adapter cable
4
HART resistance 250 Ohm (optional depending on the processing)
N
ecessary components:
l
VEGABAR
74
l
PC
with PACTware™ and suitable VEGA DTM
l
VEGACONNECT
3
or 4 with HART adapter cable (art. no.
2.25397)
l
HART
resistance approx. 250 Ohm
l
P
ower supply unit
Note:
W
ith power supply units with integrated HART resistance
(
internal resistance approx. 250 Ohm), an additional external
resistance is not necessary (e.g. VEGATRENN 149A, VEGA-
DIS
371, VEGAMET 381/624/625, VEGASCAN 693). I
n such
cases, VEGACONNECT 3 can be connected parallel to the
4 … 20
mA cable.
Connecting the PC to the
signal cable
VEGABAR
74 - 4 … 20
mA/HART
21
S
etup with PACTware™
28432
-
EN
-070718
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)