VEGA VEGABAR 65 Foundation Fieldbus User Manual
Page 57
Shock resistance
Acceleration 100 g/6 ms
13)
Electromechanical data - version IP 66/IP 67
Cable entry/plug
14)
-
Single chamber housing
l
1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5
or:
l
1 x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
l
1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5
or:
l
2 x blind stopper M20 x 1,5
-
Double chamber housing
l
1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5; plug M12 x 1 for
VEGADIS
61 (optional)
or:
l
1 x closing cap ½ NPT, 1 x blind stopper
½ NPT, plug M12 x 1 for VEGADIS 61
(optional)
or:
l
1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5; plug M12 x 1 for VEGADIS
61 (optional)
or:
l
2 x blind stopper M20 x 1.5; plug M12 x 1 for
VEGADIS
61 (optional)
Spring-loaded terminals for wire cross-sec-
tion
< 2.5 mm² (AWG 14)
Electromechanical data - version IP 66/IP 68 (1 bar)
Cable entry
-
Single chamber housing
l
1 x IP 68 cable gland M20 x 1.5; 1 x blind
stopper M20 x 1.5
or:
l
1 x closing cap ½ NPT, 1 x blind plug ½ NPT
13)
Tested according to EN 60068-2-27.
14)
Depending on the version M12 x 1, according to DIN 43650, Harting, 7/
8" FF.
VEGABAR
65 • Foundation Fieldbus
57
10 Supplement
28260
-
EN
-090522