Capacitive electrodes EK with signal conditioning instrument
Product description
0
–50
100
40
200 °C
bar
25
0
–50
100
40
°C
bar
3
2
1
EK 21 to 16 bar
Temperature
adapter
EK 42:
to 16 bar
EK 24:
from 100°C 6 bar,
max. 150°C for
30 mins.
PE
PTFE
FEP
Product temperature and operating
pressure
1)
The figures in the tables relate to the pictures
on this page. The statements on pressure
are valid for screw connections G
3
/
4
A,
3
/
4
“NPT, G 1 A, 1“NPT.
With flange versions you have to note their
nominal pressure.
All electrodes are also suitable for vacuum
(-1 bar).
For electrodes certified for Ex-Zone 0 only
PTFE and FEP are approved as isolating
material acc. to ATEX II 1/2 G EEx ia II C T6.
Mechanical connection, 1.4435 (316 L)
Isolation
Electrode type
EK 11
1
3
-
EK 21
1
3
-
EK 21 with flange
-
2
-
EK 24
-
-
2
EK 26
-
3
-
EK 26 with flange
-
2
-
EK 31
1
3
-
EK 42
-
2
-
1) For Ex-applications the permissible temperatures and pressures stated in the certificate should be noted.
Additionally note the table on the following page.
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)