beautypg.com

2 principle of operation – VEGA VEGAPULS 66 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART two-wire User Manual

Page 9

background image

3

2

1

Fig. 1: VEGAPULS 66 - flange version with plastic housing

1

Housing cover with integrated PLICSCOM (optional)

2

Housing with electronics

3

Process fitting with antenna system

T

he type label contains the most important data for identification and

use of the instrument:

l

S

ensor type

l

A

rticle and serial number device

l

A

rticle numbers documentation

l

T

echnical data: Approvals, antenna type, process fitting, process

seal/temperature, signal output, voltage supply, protection, pro-
tection class

l

SIL

identification (with SIL rating ex works)

W

ith the serial number, you can access the delivery data of the

instrument via www.vega.com, "VEGA Tools" and "serial number
search
". In addition to the type label outside, you can also find the
serial number on the inside of the instrument.

3.2 Principle of operation

VEGAPULS

66

is a radar sensor in C-band (emitting frequency

approx. 6 GHz) for continuous level measurement.

A

special version of VEGAPULS 66 is available for each area of

application. The version with flange and horn antenna is particularly

suitable for measurement of liquids and solids under extremely difficult
process conditions such as buildup, condensate and foam generation
as well as vigorous product movement.

Type label

Application area

VEGAPULS

66 • 4 … 20

mA/HART two-wire

9

3 P

roduct description

28438

-EN

-090305