VEGA VEGAVIB 31-53 User Manual
Page 10
10
VEGAVIB
Oscillators
C - Contactless (VIB E40 C, E50 C), VEGAVIB 41, 43, 51, 52, 53
Power supply
20 … 250 V AC, 50/60 Hz
20 … 250 V DC
Output
contactless electronic switch
Domestic current requirement
< 5 mA (via the load circuit)
Load current
min. 10 mA, max. 400 mA (max. 4 A up to 40 ms)
The max. permissible ambient temperature is 60°C with a load current exceeding 300 mA.
R - Relay output (VIB E30 R, E40 R, E50 R), VEGAVIB 31, 41, 43, 51, 52, 53
Power supply
20 … 250 V AC, 50/60 Hz; 20 … 72 V DC
(the max. permissible ambient temperature de-
creases linearly from 70°C to 50°C between
60 V DC and 72 V DC)
Power consumption
approx. 1 … 8 VA, max. 1.5 W
Output
relay output
Relay data:
- contact
floating spdt
- contact material
AgCdO and Au plated
- turn-on voltage
min. 10 mV
max. 250 V AC, 250 V DC
- switching current
min. 10 µA
max. 3 A AC, 1 A DC
- breaking capacitance
max. 500 VA, 54 W
T - Transistor output (VIB E40 T, E50 T), VEGAVIB 41, 43, 51, 52, 53
Power supply
10 … 55 V DC
Power consumption
max. 0.5 W
Output
floating transistor output
NPN/PNP wirable
Load current
max. 400 mA (output - overload resistant and
permanently short-circuit proof)
Voltage loss
max. 1 V
Turn-on voltage
max. 55 V DC
Blocking current
< 10 µA
Z - Two-wire output (VIB E50 Z, E50 Z Ex), VEGAVIB 51, 52, 53
Power supply
12 … 36 V DC
(power supply via VEGATOR signal conditioning
instrument)
Output
two-wire output
Current consumption
- vibrating rod free
8 mA
- vibrating rod immersed
16 mA
Suitable signal conditioning instruments
VEGALOG 571
VEGATOR 425 Ex F, 525 F, 534 Ex, 536 Ex,
537 Ex, 636 Ex, 825 Ex