VEGA Housing type 504 User Manual
Page 6
6
Housing type 504
Product description
Provide a front panel cut-out of
138
+1,0
mm x 33
+0,6
mm and insert housing type
504 into the cut-out. The Aluminium-front frame
of the housing is screwed with four small hexa-
gon screws to the steel sheet housing. The
screw heads of these hexagon screws are
additionally used to fasten the housing in the
edges of the front panel cut-out.
Turn the tension screws of the two removed
fixing hooks by some turns. Shift the fixing
hooks to the trapezoidal pins.
Keep the fixing hook with the left thomb
pushed into the trapezoidal pin (double arrow)
and turn the fixing hook with the other hand to
the right.
The fixing hook snaps into the second
trapezoidal pin. Fasten the second fixing hook
in the same way and screw the tension screw
with a 4 mm screwdriver against the front
panel wall.
Tighten the two tension screws slightly and
ensure that the four hexagon screws are in the
edges of the front panel cut-out.
Tension screw
Trapezoidal pin
turn
Housing type 504 is now ready for installation
of a series 500 instrument. Now connect the
electrical wires according to the operating
instruction of the signal conditioning instru-
ment.
hold