Philips HB591 User Manual
Page 6
ENGLISH
6
2
Place the couch on the legs carefully. Make sure the legs slide steadily into the appropriate openings in the couch (fig. 4).
◗
NB: the openings for assembling the canopy must be located at the back of the couch.
3
If necessary, you can move the couch slightly by sliding its legs across the floor or by carefully lifting it slightly off the floor together with
another person. Make sure there is enough free space beside (at least 50 cm) and behind (at least 30 cm) the appliance.
◗
Never try to move the appliance in the manner shown in the picture.This could cause the frame to become detached from the couch
(fig. 5).
4
Lift the canopy together with another person and position its connecting tubes over the connecting holes. Slide the tubes steadily into
the connecting holes of the couch (fig. 6).
B
Be careful not to get your fingers stuck between the couch and the canopy.
B
Make sure the cord does not get stuck between the couch and the canopy.
5
Remove the protective foil from the acrylic sheets of the canopy and couch (fig. 7).
6
Push the power supply unit under the couch from the front (fig. 8).
◗
NB: the plugs should be located at the back of the power supply unit. Make sure the mains cord does not get caught under the wheels.
7
Insert the large plug into the socket of the power supply unit.This will take some effort (fig. 9).
◗
Lock the plug in position by means of the metal handles (fig. 10).
8
Put the plugs of the couch and the canopy in the socket of the power supply (fig. 11).
◗
The small plugs are identical and interchangeable.
◗
If you want to remove the small plugs, follow the instructions shown in the picture (fig. 12).
9
Place the front panel and fasten it with the screws (fig. 13).
The only purpose of the panel is to enhance the appearance of the appliance.
10
Insert the mains plug of the power supply unit into the wall socket.
Using the appliance
1
Switch the appliance on by setting the required tanning time on the timer (fig. 14).
B
For the correct tanning times, see 'Tanning sessions: how often and how long?'
2
Push the canopy backwards so that you can lie down on the couch.When you are lying on the couch, pull the canopy back into
horizontal position (fig. 15).
B
NB: when the appliance has not been used for some time, the hinges of the canopy may squeak when you open or close the canopy for the first
time.
3
Switch the body cooler on by means of the switch (fig. 16).
◗
Select the desired airflow: n or b (fig. 16).
4
If you like, you can also switch on the facial tanner (fig. 17).
◗
Select , for 75% of the full intensity or m for full intensity (fig. 17).
5
Don't forget to put on the protective goggles provided.
◗
During the last minute of the session you will hear a beeping sound.
Cleaning
Always remove the mains plug from the wall socket and let the tanning appliance cool down before you start cleaning it.
Never use liquids such as alcohol, methylated spirits, petrol or acetone to clean the acrylic sheets as this may cause irreparable damage.
◗
Clean the outside of the appliance with a damp cloth.
B
Do not let any water run into the appliance.
Replacement
The light emitted by the tanning lamps will become less bright in time (i.e. after a few years in case of normal use). When this happens, you will
notice a decrease in the tanning capacity of the appliance.You can solve this problem by setting a slightly longer tanning time or by having the
tanning lamps replaced.
Have the tanning lamps and/or starters replaced by a service centre authorised by Philips.They have the knowledge and skills required for this
job and the original spare parts for your tanning appliance.
◗
If you really insist on replacing the tube lamps and/or starters yourself, you should proceed as follows:
1
Remove the mains plug from the wall socket.
2
Remove the end cover at the head of the canopy by undoing the screws (fig. 18).
3
First pull the acrylic sheet approx. 10 cm out of the appliance (1).Then undo the snap strip on the rear side of the canopy (2) (fig. 19).
4
Do the same with the snap strip on the front side of the canopy.
5
Remove the acrylic sheet (fig. 20).
◗
Now you can remove the tube lamps and the starters.
B