Dip switches setting – V-Tech DT597 Manual User Manual
Page 10
DIP Switches Setting
The DIP switch is designed to set the code
for door station and monitor, there are two
states for each DIP switch, please refer to
the sketch map.
ON(1)
=
OFF(0)
=
ON
ON
Total 2 bits can be configured, bit-1 and bit-2 are used to assign ID code for door sta-
tion.The switches can be modified either before or after installation.
There are 6 bits in total. The DIP switches are used to configure the user code
for Monitors.
Bit-6 is an video impedance match switch, which have to be set to ON if match
the impedance, otherwise set to OFF.
Bit-1~Bit-5 are used to set user code, for DT597 door station, the user code
should be set to 0~15.
Please refer to the following settings:
Door station DIP setting
Indoor monitor DIP setting
Bit state
Descriptions
Default setting, ID = 0(00), set to the first Door Station.
ID = 1(10), set to the second Door Station.
ID = 2(01), set to the third Door Station.
ID = 3(11), set to the fourth Door Station.
1 2
ON
1 2
ON
1 2
ON
1 2
ON
-10-