Dell 7700HD Projector User Manual
Page 7
tion
pdmAudio pdmAudioVolume
.1.3.6.1.4.1.2699.2.4.1.16.2.0 Integer
R/W
pdmAudio
pdmAudioMute
.1.3.6.1.4.1.2699.2.4.1.16.3.0
Integer R/W
pdmAudio
pdmAudioTreble .1.3.6.1.4.1.2699.2.4.1.16.4.0
Integer R
DEFVAL { 0 }
pdmAudio
pdmAudioBass
.1.3.6.1.4.1.2699.2.4.1.16.5.0
Integer R
DEFVAL { 0 }
pdmAudio
pdmAudioBalance .1.3.6.1.4.1.2699.2.4.1.16.6.0
Integer R
DEFVAL { 0 }
pdmAlert
pdmAlertIndex
1.3.6.1.4.1.2699.2.4.1.18.1.1.1.1
Integer not-accessible 1
pdmAlert
pdmAlertGroupTy
pe
1.3.6.1.4.1.2699.2.4.1.18.1.1.2.1 String
R
See
Note
1
pdmAlert
pdmAlertGroupId 1.3.6.1.4.1.2699.2.4.1.18.1.1.3.1
String
R
See Note 1
pdmAlert
pdmAlertCode
1.3.6.1.4.1.2699.2.4.1.18.1.1.4.1
String
R
DEFVAL { "" }
pdmAlert
pdmAlertDescripti
on
1.3.6.1.4.1.2699.2.4.1.18.1.1.5.1
String
R
Alert's condition has lamp Fail,
Lamp hours running out,
Projector Overheating, Lamp
Overheating and Fan Error.
pdmAlert
pdmAlertSeverityL
evel
1.3.6.1.4.1.2699.2.4.1.18.1.1.6.1 Integer
R
See
Note
1
pdmAlert
pdmAlertTraining
Level
1.3.6.1.4.1.2699.2.4.1.18.1.1.7.1
Integer R
DEFVAL { 2 }
pdmAlert
pdmAlertDateTim
e
1.3.6.1.4.1.2699.2.4.1.18.1.1.8.1 String
R
DEFVAL
{ "1980-01-01T00:00:00" }
pdmAlert
pdmAlertPowerOn
Count
1.3.6.1.4.1.2699.2.4.1.18.1.1.9.1
String
R
DEFVAL { "" }
pdmAlert
pdmAlertSysUpti
me
1.3.6.1.4.1.2699.2.4.1.18.1.1.10.1
String
R
DEFVAL { "" }
pdmAlert
pdmAlertCriticalA
lertsCount
1.3.6.1.4.1.2699.2.4.1.18.2.0
Integer R
pdmAlert
pdmAlertAllAlerts
Count
1.3.6.1.4.1.2699.2.4.1.18.3.0 Integer
R
Note 1:
a) If there is no any current alert, all of OID in alert table will respond default value.
pdmAlertGroupType =” “
pdmAlertGroupID = 0
pdmAlertSeverity = other (1)
The reset Object will respond default.
b) If there is FAN alert happen, the tables is shown below.
pdmAlertGroupType =” Fan”
pdmAlertGroupID = “Fan Error”
pdmAlertSeverity = Critical (3)
The rest Object will respond default.
c) If there is Lamp fail alert happen, the tables is shown below.
pdmAlertGroupType = “Lamp”
pdmAlertGroupID= Lamp Fail
pdmAlertSeverity = Critical (3)
The rest Object will respond default.
d) If there is Lamp hours running out alert happen, the tables is shown below.
pdmAlertGroupType = “Lamp”
pdmAlertGroupID= Lamp hours running out
pdmAlertSeverity = warning (4)
The rest Object will respond default.
e) If there is Projector Over-heating alert, the tables is shown below.
pdmAlertGroupType = “ThermalSensor”
pdmAlertGroupID= “Projector Overheating”
pdmAlertSeverity = warning (4)
The rest Object will respond default.
f) If there is Lamp Over-heating alert, the tables is shown below.
pdmAlertGroupType = “ThermalSwitch”
pdmAlertGroupID= “Lamp Overheating”
pdmAlertSeverity = Critical (3)
The rest Object will respond default.
Information in this document is subject to change without notice.
© 2012 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell and the DELL logo are trademarks of Dell Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or
their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.