beautypg.com

Dell POWEREDGE R805 User Manual

Page 15

background image

Getting Started With Your System

13

Environmental

NOTE:

For additional information about environmental measurements for specific

system configurations, see

www.dell.com/environmental_datasheets.

Temperature

Operating

10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour

NOTE:

For altitudes above 2950 feet, the maximum

operating temperature is derated 1ºF/550 ft.

Storage

–40° to 65°C (–40° to 149°F) with a maximum
temperature gradation of 20°C per hour

Relative humidity

Operating

20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour

Storage

5% to 95% (noncondensing) with a maximum
humidity gradation of 10% per hour

Maximum vibration

Operating

0.26 Grms at 5–350 Hz in operational
orientations

Storage

1.54 Grms at 10–250 Hz in all orientations

Maximum shock

Operating

One shock pulse in the positive z axis (one pulse
on each side of the system) of 31 G for 2.6 ms
in the operational orientation

Storage

Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 71 G for up to 2 ms

Altitude

Operating

–16 to 3048 m (–50 to 10,000 ft)

NOTE:

For altitudes above 2950 feet, the maximum

operating temperature is derated 1ºF/550 ft.

Storage

–16 to 10,600 m (–50 to 35,000 ft)