Specifi cations – Olympus FL-600R User Manual
Page 21
EN
23
Specifi cations
Specifi cations
MODEL NO.
: FL-600R
Product type
: External electronic fl ash for digital still camera
Guide number
: 36 (ISO100), 12 (ISO100, using the wide panel)
Firing angle
: Covers the angle of view of 12–42 mm lenses (equivalent to 24–85 mm in
135 format)
(With wide panel: 8 mm lens, equivalent to 16 mm in 135 format)
Flash modes
: TTL-AUTO, AUTO, MANUAL, FP TTL AUTO, FP MANUAL,
SL AUTO, SL MANUAL, RC
Flash emission period : Approx. 1/20000 to 1/500 seconds (except in Super FP fl ash)
Flash emission count
(at full activation)*
: Approx. 250 times (using AA (R6) alkaline batteries)
Approx. 370 times (using AA (R6) NiMH batteries)
Recharge time
: Approx. 2.5 seconds (using AA (R6) alkaline batteries)
Approx. 2 seconds (using AA (R6) NiMH batteries)
(from full activation to CHARGE lamp lighting)*
AF illuminator
: Effective range: Approximately 1–5 m (varies with camera and lens used)
Operating
environment
: Temperature: –10 to 42°C (14 to 108°F)
Humidity: 20 to 90%
Dimensions
: 62 (W) × 104 (H) × 98 (D) mm/2.4 Ч 4.1 Ч 3.9 in. (excluding protrusions)
Weight
: 255 g (9 oz.) (excluding batteries)
* Measurements obtained from in-house tests at Olympus. Actual fi gures may vary depending on
shooting conditions.