9.0. Commands

9.1. CCID Command Pipe Bulk-OUT Messages

ACR38x (CCID) shall follow the CCID Bulk-OUT Messages as specified in CCID Rev 1.0 Section 4.1.

In addition, this specification defines some extended commands for operating additional features.
This section lists the CCID Bulk-OUT Messages to be supported by ACR38x (CCID).

9.1.1.

PC_to_RDR_IccPowerOn

This command activates the card slot and returns ATR data from the card.

Offset

Field

Size

Value

Description

0

bMessageType

1

62h

1

dwLength

4

00000000h Size of extra bytes of this message.

2

bSlot

1

Identifies the slot number for this

command.

5

bSeq

1

Sequence number for command.

6

bPowerSelect

1

Voltage that is applied to the ICC:
00h = Automatic Voltage Selection
01h = 5 volts
02h = 3 volts

7

abRFU

2

Reserved for future use.


The response to this command message is the RDR_to_PC_DataBlock response message and the

data returned is the Answer To Reset (ATR) data.

9.1.2.

PC_to_RDR_IccPowerOff

This command deactivates the card slot.

Offset

Field

Size

Value

Description

0

bMessageType

1

63h

1

dwLength

4

00000000h Size of extra bytes of this message.

5

bSlot

1

Identifies the slot number for this

command.

6

bSeq

1

Sequence number for command.

7

abRFU

3

Reserved for future use.


The response to this message is the RDR_to_PC_SlotStatus message.

9.1.3.

PC_to_RDR_GetSlotStatus

This command gets the current status of the slot.

Offset

Field

Size

Value

Description

0

bMessageType

1

65h

1

dwLength

4

00000000h Size of extra bytes of this message.