Meazura MEZ1000 Specifications:
Operating System:
Palm OS 4.1.2
Memory:
16MB SDRAM, 4MB Flash
Display:
160x160 pixel grayscale, backlit
Communications:
USB (cable provided)
Serial (1.2-115Kbs)
IrDA Infrared (1.2-115.2Kbs)
Battery
3.6V Li-Ion 1900mAh
Sealing
IP67 – submersible to 1 meter (30 min)
Current Consumption 21 mA (backlight off) unit ON (excluding
module)
2 mA Sleep mode
Meazura unit or for additional accessories.
ETS Module Specifications:
406 receiver range:
-60dBm to +36dBm (5W)
Power source:
Meazura internal battery
Decoding:
per COSPAS/SARSAT C/S T.001
Issue 3 Rev. 5
Current Consumption
10mA unit ON
<100nA Sleep mode
Calibration
The ETS is factory calibrated and does not require periodic re-calibration.