beautypg.com

Ets main screen view software screen view – ACR&Artex ELT Test Set (ETS) User Manual

Page 17

background image

Artex Products / ACR Electronics, Inc.

570-1000 Rev C

Page 13 of 24

NOTE: The ELT read function does not detect or verify the presence of

121.5 MHz; this is a 406 MHz reader ONLY.













ETS Main Screen View


The reader is now ready to receive and decode the message. Select “measure”
from “Avionic Tools” screen as shown below. The screen will display “Waiting for
Data” as shown on next page until a valid ELT transmission is received. Perform
a “Self Test” of the ELT by turning the ELT local or remote switch from
“OFF/ARMED” to “ON” for no more than 3 sweeps of the 121.5/243 MHz signal
and then switch back to “OFF/ARMED”. If the received data is invalid, then
“Message Error!” will be displayed. This may indicate excessive distance from
the ELT antenna if testing externally. 0-30 feet distance from the ELT antenna is
recommended, although distances up to 50 feet are possible (as allowed). The
ELT internal 406 MHz oscillator may also need to warm-up. Repeat the ELT test if
necessary.

Software Screen View

Sarcalc Icon