Section 3, Installation, Preparation – ACR&Artex ThunderBird SSAS User Manual
Page 6: Beacon installation
Y1-03-0180 Rev. D
3
From Any Location
USCG Headquarter Command Center
Tel: (800) 323-7233
For Canadian Pacific waters:
Canadian Coast Guard Rescue Coordination Centre Victoria
Tel: (800) 567-5111
For Canadian Atlantic waters:
Canadian Coast Guard Rescue Coordination Centre Halifax
Tel: (800) 565-1582
For other Canadian waters (Great Lakes, Hudson’s Bay, and Arctic)
Canadian Coast Guard Rescue Coordination Centre Trenton
Tel: (800) 267-7270
2.2.2
To report false alarms worldwide contact your national authority.
SECTION 3 - INSTALLATION
3.1
Preparation
3.1.1
Parts included:
Beacon/mounting bracket assembly
Qty: 1
PN: A3-06-2410-1
Cross dipole antenna
Qty: 1
PN: 2810
SMA male conn, RG-8/U crimp
Qty: 1
PN: 2814
Activation switches
Qty: 2
PN: 2820
Antenna mount
Qty: 1
PN: 2821
TNC male conn, RG-8/U crimp
Qty: 1
PN: 2633
Insulated terminals, crimp
Qty: 4
PN: A1-05-0125-17
3.1.2
Tools needed:
Phillips screwdriver
Drill
RG-8/U crimp tool
Saw
Solder iron
3.1.3
Additional materials needed for installation:
Marine grade RG-8/U coaxial cable
Switch wire or cable
Screws/Bolts for mounting bracket (3/16” or #10)
Screws/Bolts for antenna mount
Boeshield T-9 or equivalent waterproof lubricant
3.2
Beacon installation
3.2.1
The ThunderBird SSAS is shipped attached to its mounting bracket. Typically, the beacon must be
removed from the mounting bracket during installation. The beacon can be removed from the mounting
bracket as follows:
First disconnect the 2-Pin waterproof connector on the left side of the beacon.
Unbuckle the strap holding the beacon to the bracket.
The ThunderBird SSAS is intended to transmit covertly a security alert, notifying competent authorities
that the security of the vessel is under threat or has been compromised. A key component of the system is
its covert nature, which should be maintained as much as possible to protect the beacon from malicious
tampering. The ThunderBird SSAS
is shipped in the “OFF” position. During the installation procedure,
leave the beacon
in the “OFF” position to prevent false alarms.