Injector tables dest. uk category ii2h 3 – Candy OVG 505__2 X User Manual
Page 8
INJECTOR TABLES
Dest.
UK
CATEGORY II2H
3+
Gas pressure (mbar)
Type of gas used
Type of
burner
Air setting
By
-pass
marking
(100/mm)
Injector
marking
(100/mm)
Nominal heat
capacity (kW)
Nominal
consumption
Air necessary
for
combustion
m³/h
Reduced
nominal heat
capacity
(kW)
min.
nominal
max.
LIQUEFIED
PETROLEUM
GAS
(Butane)
G30
Oven
Open
48
80
2,70
196 g/h
5,4
0,80
20
28
-30
35
LIQUEFIED
PETROLEUM
GAS
(Propane)
G31
Oven
Open
48
80
2,70
193 g/h
5,4
0,80
25
37
45
NATURAL GAS
(Methane)
G20
Oven
Open
48 adjusted
115
2,70
257 l/h
5,4
0,80
17
20
25
Gas pressure (mbar)
Type of gas used
Type of
burner
Air setting
By
-pass
marking
(100/mm)
Injector
marking
(100/mm)
Nominal heat
capacity (kW)
Nominal
consumption
Air necessary
for
combustion
m³/h
Reduced
nomin
al heat
capacity (kW)
min.
nominal
max.
LIQUEFIED
PETROLEUM
GAS
(Butane)
G30
Grill
Open
-
80
2,40
175 g/h
4,8
-
20
28
-30
35
LIQUEFIED
PETROLEUM
GAS
(Propane)
G31
Grill
Open
-
80
2,40
172 g/h
4,8
-
25
37
45
NATURAL G
AS
(Methane)
G20
Grill
Open
-
115
2,40
229 l/h
4,8
-
17
20
25