Candy OVG 505__2 X User Manual
Page 10
Installation room (fig. 1)
For proper operation of the gas appliance, it is essential that the room has a
natural air flow from openings on the external walls providing sufficient air for
combustion of the gas. These openings must have a free air-flow cross-section of
at least 100 cm2 (realized with one or more openings).
The exhaust of the combustion residual products must occur through hoods
connected to chimney flues or directly to the outdoors. If it is not possible to
install a hood, an electric fan must be applied to the external wall or window of
the room provided that the room has the required air inlet openings according to
current standards. This electric fan must have a capacity that guarantees, for a
kitchen, an hourly air renewal of 3-5 times its volume.
Fig. 1