Guarantee, Environment and recycling, 3 technical data – STIEBEL ELTRON CNS 50 S 26.01.2009 - 10.05.2009 User Manual
Page 10: 4 electrical connection, 5 handover
![background image](/manuals/238338/10/background.png)
10
3 Technical data
Type
CNS 50 S
CNS 50 U
CNS 75 S
CNS 75 U
CNS 100 S
CNS 100 U
CNS 125 S
CNS 125 U
CNS 150 S
CNS 150 U
CNS 175 S
CNS 175 U
CNS 200 S
CNS 200 U
CNS 250 S
CNS 250 U
CNS 300 S
CNS 300 U
Height
mm
450
Width
mm
370
445
445
590
590
740
740
890
1040
Depth
with wall bracket
mm
78
100
Dimension
A
mm
121
195
195
343
343
491
491
639
787
Weight
kg
3,0
4,2
4,2
5,6
5,6
7,0
7,0
8,4
9,8
Connection
1/N ~ 230 V
Power
kW
0,5
0,75
1,0
1,25
1,5
1,75
2,0
2,5
3,0
Temperature
adjustment range
ºC
approx. 6 to 30
Frost protection
ºC
approx. 6
Protection class
II
Protection mode
IP 24, splash water protected
Approval
see unit rating palte
2.4 Electrical connection
The required electrical connection is AC 230V.
For fixed connection, an earth socket or junc-
tion box should be installed at a distance of at
least 100 mm to the side of the heater.
2.5 Handover
Explain to the user how the unit functions.
Draw his attention in particular to the safety
instructions.
Give the user these operating and usage in-
structions.
Guarantee
For guarantees please refer to the respective terms and conditions
of supply for your country.
!
The installation, electrical connection and first operati-
on of this appliance should be carried out by a qualified
installer.
!
The company does not accept liability for failure of any
goods supplied which have not been installed and ope-
rated in accordance with the manufacturer‘s instructions.
Environment and recycling
Please help us to protect the environment by disposing of the
packaging in accordance with the national regulations for waste
processing.