4. Fault rectification
by thequalified installer
Fault
Info
Rectification
Establish voltage supply.
No voltage.
No hot water.
Low mixed water volumes.
Temperature setting too low.
Increase the temperature setting.
Heating element blocked with limescale.
Remove limescale from the heating element.
Small throughflow.
Dirt contamination or limescale deposits on
the perlators in the fittings or the shower
heads.
Clean and/or clear the limescale from the
outlet fittings.
„SERVICE ANODE“ signal lamp lights up.
Signal anode used up.
Check the signal anode and replace it if
necessary.
Table 3
3. Fault rectification
by the user
Fault
Info
Rectification
Check the fuses in the house electrical
installation.
No voltage.
No hot water.
Low mixed water volumes.
Temperature setting too low.
Increase the temperature setting.
Table 2
„SERVICE ANODE“ signal lamp lights up.
Signal anode used up.
Arrange for the qualified installer to check
the signal anode and replace it if necessary.
Heating element blocked with limescale.
Arrange for the qualified installer to remove
limescale from the heating element.
Small throughflow.
Dirt contamination or limescale deposits on
the perlators in the fittings or the shower
heads.
Clean and/or clear the limescale from the
outlet fittings.
6. Environment and
recycling
5. Guarantee
For guarantees please refer to the pespective
terms and conditions of supply for your
country.
The installation, electrical connection
and first operation of this appliance
should be carried out by a qualified
installer.
The company does not accept liability for
failure of any goods supplied which accor-
dance with the manufacturer's instructions.
Recycling of obselete appliances
Appliances with this label must not
be disposed off with the general
waste. They must be collected
separately and disposed off according to local
regulations.