Led diagnostic, General safety rules – RIDGID RBC 10 Li-Ion Charger User Manual
Page 8

LED Diagnostic
Solid Light
Meaning
Blinking Light
—
Yellow
Charger is plugged in with no battery installed -
ready to charge.
Yellow (2 Seconds)
—
Battery condition is being checked by the charger.
—
Green (Slow)
Battery is being charged. Charge level ‹85%.
—
Green (Fast)
Battery is being charged. Charge level ›85%.
Green
—
Battery fully charged.
—
Red
Battery is misaligned in charger. Remove battery
and reinsert onto charger.
Battery is damaged. See
Accessories Section to
select an appropriate replacement battery. See
Recycling Section for disposal instructions.
Charger is damaged. See
Service and Repair sec-
tion for contact information.
Red
—
Battery or charger outside of charging range (41°F
(5°C) to 95°F (35°C)). Allow battery and charger to
reach temperature range by sitting in a conditioned
environment.
NO LEDs ON
Charger does not have power. Ensure that charger
is properly connected to electrical outlet.
Charger is defective. See
Service and Repair
Section for contact information.
Charger
Icon
Figure 3 – Warning Label Location on Battery
General Safety Rules
WARNING
Read all safety warnings and all instructions. Failure to fol-
low the warnings and instructions may result in electric
shock, fire and/or serious injury.
SAVE ALL WARNINGS AND INSTRUCTIONS
FOR FUTURE REFERENCE!
Work Area Safety
• Keep your work area clean and well lit. Cluttered or
dark areas invite accidents.
• Do not operate electrical devices in explosive at -
mos pheres, such as in the presence of flam mable
liquids, gases, or dust. Electrical devices create
sparks which may ignite the dust or fumes.
• Keep children and by-standers away while oper-
ating a power tool. Distractions can cause you to
lose control.
Electrical Safety
• Electrical devices plugs must match the outlet.
Never modify the plug in any way. Do not use any
RBC 10 Li-Ion Battery Charger
6
Ridge Tool Company