8 troubleshooting – Graco AquaMax-E 3050 User Manual
Page 16

16
1)
Options / model variants
Original instructions
English
8 Troubleshooting
Fault
Cause
Remedy
Pressure drop
•
Air in the system
•
Vent the system by operating
the spray gun several times at
short intervals. If necessary,
operate the cleaner for a short
time without the high-pressure
hose connected.
•
High pressure nozzle blocked
worn
•
Clean/replace the high pres-
sure nozzle
•
Detergent tank empty
•
Top up detergent tank or set
detergent metering to “0”
Pressure fluctuations
•
Pump draws in air (only pos-
sible in suction mode)
•
Check that the suction set is
air-tight
•
Lack of water
•
Open water tap
•
Water inlet hose is too long or
its cross-section too small
•
Use specified water inlet hose
•
Lack of water caused by
blocked water filter
•
Clean the water filter in the
water connection (never work
without water filter)
•
Lack of water because max.
permissible suction height has
not been heeded
• See
instructions
The motor does not start when the
cleaner is switched on
•
The plug is not inserted prop-
erly, i.e. there is no current
•
Check the plug, lead and
switch and if necessary have
them replaced by a trained
electrician
•
The mains fuse is switched off •
Switch on the mains fuse
When the cleaner is switched on
the motor buzzes without starting
•
The mains voltage is too low or
there is a phase failure.
•
Have the electrical connection
checked
•
The pump is blocked or frozen •
Contact the GRACO customer
service
•
Incorrect cross-section or
length of the extension lead
•
Use lead with correct cross
section or length
The motor switches off
•
The overload protection has
been activated due to over-
heating or overloading of the
motor
•
Check that the mains volt-
age and the cleaner voltage
are the same. Switch off the
cleaner and allow it to cool for
at least 3 minutes
•
High-pressure nozzle is dirty
•
Change the high-pressure
nozzle
No detergents drawn in
•
Injector is dirty or suction hose
is blocked
• Clean
•
Detergent tank empty
•
Top up detergent tank
•
The cap on the FlexoPowerJet
nozzle is not set to low pres-
sure
•
See chapter 4.