Repair and customer service, Warranty and liability, Declaration of conformity – Fein ABS_18C User Manual
Page 17: Environmental protection, disposal

17
en
Handling the battery.
Operate and charge the battery only within the battery
operating-temperature range of 0°C – 45°C (32°F –
113°F). At the beginning of the charging procedure, the
battery temperature must be within the battery operat-
ing-temperature range.
The real percentage of the battery charge condition is
only indicated when the power tool motor is stopped.
The electronics automatically switch off the motor prior
to the battery being deep discharged.
Repair and customer service.
When working metal under extreme operat-
ing conditions, it is possible for conductive
dust to settle in the interior of the power tool.
Blow out the interior of the power tool via the ventila-
tion slots frequently with dry and oil-free compressed air.
The current spare parts list for this power tool can be
found in the Internet at www.fein.com.
If required, you can change the following parts yourself:
application tools, battery
Warranty and liability.
The warranty for the product is valid in accordance with
the legal regulations in the country where it is marketed.
In addition, FEIN also provides a guarantee in accordance
with the FEIN manufacturer’s warranty declaration.
The delivery scope of your power tool may include only
a part of the accessories described or shown in this
Instruction Manual.
Declaration of conformity.
FEIN declares itself solely responsible for this product
conforming with the relevant provisions given on the last
page of this Instruction Manual.
Technical documents at: C. & E. FEIN GmbH, C-DB_IA,
D-73529 Schwäbisch Gmünd
Environmental protection, disposal.
Packaging, worn out power tools and accessories should
be sorted for environmental-friendly recycling.
Dispose of batteries only when discharged.
For batteries that are not completely discharged, insulate
the terminals with tape as a protective measure against
short-circuiting.
LED indicator
Meaning
Activity
1 – 4 green
LED
Percentage of
charge condition
Operation
Continuous
red light
Battery is almost
empty
Charge battery
Red flashing
light
Battery is not
ready for opera-
tion
Bring the battery
into the battery
operating-tem-
perature range,
then charge
OBJ_BUCH-0000000105-001.book Page 17 Thursday, April 4, 2013 10:23 AM