Festool CT 36 E-LE-AC CLEANTEX User Manual
Page 14

14
CLEANTEX
GB
6.2
Switch on/off
X
Insert the plug into an earthed socket.
The switch
[1-7]
serves as an on/off switch.
Switch position "0"
Appliance socket
[1-3]
is disconnected from
the power, mobile dust extractor is switched
off.
"MAN" switch position
Appliance socket
[1-3]
is connected to the
power, the mobile dust extractor starts.
"Auto" switch position
Appliance socket
[1-3]
is connected to the
power, the mobile dust extractor starts when
the connected tool is switched on.
7
Settings
7.1
Connecting electric power tools
X
Connect the electric power tool to the ap-
pliance socket
[1-3]
.
7.2
Connecting pneumatic tools
If the compressed air module
[1-2]
(496141)
is installed, the automatic switch-on function
of the mobile dust extractor also works in
combination with pneumatic tools.
We also recommend installing the VE service
unit (495886). The service unit filters and lu-
bricates the compressed air and enables an
adjustment of the air pressure. An IAS
adapter (454757) is available to connect Fes-
tool pneumatic tools to the IAS system.
The operating pressure of the tool must be
6 bar for the automatic switch-on unit to
function correctly.
7.3
Adjusting the suction power
You can use the suction power adjuster
[1-8]
to adapt the machine suction power to differ-
ent applications.
7.4
Applying the brake
Folding out the black brake lever
[1-12]
pre-
vents the mobile dust extractor from rolling.
To achieve this, lift the front end of the mo-
bile dust extractor slightly and push the
black brake lever downwards until it latches
into place. Push the green lever
[1-11]
again
to release.
7.5
Temperature cut-out
To prevent overheating, a temperature cut-
out switches the mobile dust extractor off
when it reaches a critical temperature.
X
Switch off the mobile dust extractor and
allow to cool for about 5 minutes.
L If the mobile dust extractor will not switch
on again, please contact a Festool service
workshop.
8
Working
8.1
Handling
Hose store: after finishing work, you can
feed the suction hose through the recess
[4-
3]
and place it in the hose store. You can do
the same with the mains cable through the
other recess
[4-2]
.
SysDoc Systainer attachment system: a
Systainer can be attached to the storage
area via the two slides
[4-1]
.
8.2
Extracting dry materials
The filter element will become damp when
fluids are extracted. A damp filter element
will clog more quickly when dry materials are
extracted. Therefore, dry the filter element
before extracting dust or replace the damp
filter with a dry one.
8.3
Extracting fluids
Before extracting fluids, remove the filter or
disposal bag (see chapter 9.1). We recom-
mend using a special wet filter.
WARNING
Risk of injury from tools starting up un-
expectedly
X
Before setting the switch to the "AUTO" or
"MAN" position, make sure that the con-
nected tool is switched off.
WARNING
Risk of injury
X
Observe the maximum connected loads
for the appliance socket (see chapter
"Technical data").
X
Make sure that the power tool is switched
off before connecting or disconnecting.
WARNING
Risk of injury
X
Make sure that the pneumatic tool is
switched off before connecting or discon-
necting.