Jotul I80RH Panorama User Manual
Page 10

10
Table of contents
1.0 Relationship to the authorities ...................... 10
2.0 Technical data ................................................ 10
3.0 Safety precautions ......................................... 11
4.0 Installation .................................................... 11
5.0 Operation instructions ................................... 13
6.0 Maintenance .................................................. 14
7.0 Service ............................................................. 15
8.0 Optional Equipment ..................................... 15
9.0 Operational problems - troubleshooting ..... 17
Figures .................................................................. 67
1.0 Relationship to the
authorities
Installation of a fireplace must be according to local codes and
regulations in each country.
All local regulations, including thosethat refer to national and
European standards, shall be complied with when installing the
product.
Instructions for mounting, installation and use are enclosed with
the product. Prior to using the product the installation must be
inspected by a qualified person.
A product data label in heat resistant material is located on the
heat shield at the back of the product. This contains information
about identification and documentation for the product.
2.0 Technical data
Material: Cast
iron
Finish: Paint
Fuel: Wood
Log length, max.:
50 cm
Flue outlet:
Top
Flue dimension
(outside the outlet) :
200 mm/314 cm
2
cross section
Approx. weight:
125 kg
Optional extras:
Fire screen, damper complete, side
plates aluminium, ash solution,
assembly kit for cassette
Dimensions, distances etc.: See fig.1
Technical data according to EN 13229
Nominal heat output:
9,0 kW
Smoke gas mass flow:
8,4 g/s
Recommended chimney draught:
12 Pa
Effiency: 71%@9,0
kW
CO emission (13% O
2
): 0,25
%
Flue gas temperature:
350
0
C
Operating mode:
Intermittent
ENGLISH