Multifunctional settings

Item

Description

SERVICE

Selecting this item displays the SERVICE menu.

Select an item using the buttons ▲/▼, and press the button ► or the

ENTER button on the remote control to execute the item.

FAN SPEED  AUTO ADJUST  GHOST  KEY LOCK  FILTER MESSAG  FACTORY RESET

FAN SPEED

Using the buttons ▲/▼ switches the rotation speed of the cooling fans. The

HIGH is the mode for use at highlands etc. Note that the projector is noisier

when the HIGH is selected.

HIGH  NORMAL

AUTO ADJUST

Using the buttons ▲/▼ enables/disables the automatic adjustment.When

DISABLE is selected, the automatic adjustment feature is disabled, although

rough adjustment is automatically performed depending on the basic setting.

ENABLE  DISABLE

• Depending on conditions, such as input image, signal cable to the projector,

environment around the projector, etc., the automatic adjustment may not work

correctly. In such a case, please choose DISABLE to disable the automatic

adjustment, and make adjustment manually.

GHOST

1. Select a color element of ghost using the buttons ◄/►.

2. Adjust the selected element using the buttons ▲/▼ to disappear ghost.

KEY LOCK

Using the buttons ▲/▼ turns on/off the key lock feature. When TURN ON is selected, the

buttons on the projector except the STANDBY/ON button are locked.

TURN ON  TURN OFF

• Please use to avoid a mischief and touching accidentally. This function

does not have any effect on the remote control.

FILTER MESSAGE

Use the ▲/▼ button to set the timer for the interval to show the message for

cleaning up the air filter.

50h  100h  200h  300h  TURN OFF

After selecting “50h”, 100h”, “200h”, or “300” , the message “CLEAN THE

AIR FILTER” will appear after the timer reaches the interval time set by the

menu. Please refer to the “FILTER TIME” item (36) and the table “Related

message” (42)

When the “TURN OFF” is chosen, the air-filter cleaning message will not appear.

• Please check and clean the air filter periodically, even if there is no

message. If the air filter becomes blocked by dust or others, the internal

temperature will rise, which could cause malfunction, or reduce the lifetime

of the projector.

• It is recommended to choose “100h” in general. Please be careful with the

operating environment of the projector and the condition of air filter, especially

when the “200h”, “300h” or “TURN OFF” is chosen.

FACTORY RESET

Selecting RESET using the button ▲ performs this function. By this function, all the

items in all of menus will collectively return to the initial setting. Note that the items

LAMP TIME, FILTER TIME and LANGUAGE are not reset.

RESET  CANCEL