Tannoy V300 User Manual
Page 16

13.3 Biamp System Parameters
Parameter
Unit/Name
Low Section
High Section
Gain
(dB)
0
-6
Delay
(ms)
0
0
Polarity
Positive
Positive
HPF
â
Freq (Hz)
45.1
1920
Slope (dB/oct)
24
24
Filter Shape
Butterworth
Linkwitz Riley
LPF
Freq (Hz)
1820
Thru
Slope (dB/oct)
24
NA
Filter Shape
Linkwitz Riley
NA
Freq (Hz)
60.1
6100
Level (dB)
+7
+3.5
Type
Parametric
Hi - Shelf
PEQ 1
в
в
Q / Bandwidth
2.8 / 0.3536
NA
Freq (Hz)
281
10500
Level (dB)
-2.5
+4
Type
Parametric
Parametric
PEQ 2
Q / Bandwidth
2 / 0.500
9.5 / 0.1051
Freq (Hz)
749
NA
Level (dB)
-2
NA
Type
Parametric
NA
PEQ 3
Q / Bandwidth
2 / 0.500
NA
Freq (Hz)
606
NA
Level (dB)
-2
NA
Type
Parametric
NA
PEQ 4
Q / Bandwidth
6 / 1.669
NA
Freq (Hz)
1650
NA
Level (dB)
-2
NA
Type
Parametric
NA
PEQ 5
Q / Bandwidth
7.1 / 0.1403
NA
в
в
Note : When using the V300 with subs, set HPF on LF section @ 80 – 100Hz
(24dB/oct LR) and omit PEQ1 (on LF only)
PEQ 1 (on LF only) may also be omitted when using the V300 as a floor monitor.