beautypg.com

Indicator lamps" ( ) for details.), Regarding the indicator lamps – 3M MP7640i/MP7740i User Manual

Page 36

background image

WHAT TO DO WHEN YOU THINK A MACHINE DEFECT HAS OCCURRED (continued)

Regarding the Indicator Lamps

Lighting and flashing of the POWER indicator, the LAMP indicator, and the
TEMP indicator have the meanings as described in the Table below.
Please respond in accordance with the instructions within the Table.

POWER

indicator

LAMP

indicator

TEMP

indicator

Description

The orange

lamp is lighted

Turned OFF

(Not lighted)

Turned OFF

(Not lighted)

The STANDBY mode is set

Flashing of the green lamp

Turned OFF

Turned OFF

The unit is warming up. Please wait.

The green lamp is lighted

Turned OFF

Turned OFF

The unit is in an ON state. Ordinary operations may be performed.

Flashing of the orange lamp

Turned OFF

Turned OFF

The unit is cooling down. Please wait.

Blinking of the

red lamp

-

-

The unit is cooling down. Please wait.
A certain error has been detected. Wait until the POWER indicator lamp has finished
flashing, and then perform the proper response measure using the item descriptions
below as reference.

The red lamp

is lighted, or

blinks

The red lamp

is lighted

Turned

OFF

The lamp does not light.
There is a possibility that the interior portion has become heated. Turn the power OFF and wait
approximately 20 minutes. After the main unit has cooled down, please confirm whether or not
there is blockage of the air passage aperture, whether or not the filter is dirty, and/or whether or
not the peripheral temperature exceeds 35°C, etc. After performing any needed maintenance,
turn the power ON again; if the same display is displayed, then please change the lamp.

The red lamp

is lighted, or

blinks

Blinking of the

red lamp

Turned

OFF

Either there is no lamp and/or lamp cover, or either of these has not been properly fixed
(attached). Turn the power OFF and wait approximately 45 minutes. After the main unit has
sufficiently cooled down, please make confirmation of the attachment state of the lamp and
lamp cover. After performing any needed maintenance, turn the power ON again; if the same
display is displayed, then please contact a sales store or a service company.

The red lamp

is lighted, or

blinks

Turned

OFF

Blinking of the

red lamp

The cooling fan is not operating. Turn the power OFF and wait approximately 20 minutes. After the
main unit has cooled down, please make confirmation that no foreign matter has become caught in
the fan, etc. After performing any needed maintenance, turn the power ON again; if the same display
is displayed, then please contact a sales store or a service company.

The red lamp is

lighted, or

blinks

Turned

OFF

The red lamp is

lighted

There is a possibility that the interior portion has become heated. Turn the power OFF and wait
approximately 20 minutes. After the main unit has cooled down, please confirm whether or not
there is blockage of the air passage aperture, whether or not the filter is dirty, and/or whether or
not the peripheral temperature exceeds 35°C, etc. After performing any needed maintenance,
turn the power ON again; if the same display is displayed, then please contact a sales store or a
service company.

The green lamp

is lighted

Alternative blinking

with the red lamp

There is a possibility that the interior portion has become overcooled. Please use the unit within
the usage temperature parameters (0°C to 35°C). After performing any needed maintenance,
turn the power ON again; if the same display is displayed, then please contact a sales store or a
service company.

The green

lamp is lighted

Simultaneous blinking

with the red lamp

This is a notification that it is time to clean the filter.
After cleaning the filter, operate the FILTER TIME portion of the OPTION Menu, and perform
reset of the FILTER TIME.

When the interior portion has become overheated, for safety purposes, the power source is automatically turned OFF, and the
indicator lamps may also be turned OFF. Press the “ ” (power OFF) side of the main power switch, and wait for approximately 20

minutes. Please then use the unit only after having first confirmed that the unit has sufficiently cooled down.

NOTE

35