Conversion from natural gas to lpg – Zanussi ZAF 42 User Manual
Page 18
![background image](/manuals/231063/18/background.png)
19
Conversion from Natural Gas to LPG
It is important to note that this model is designed for
use with natural gas but can be converted for use with
butane or propane gas providing the correct injectors
are fitted. The gas rate is adjusted to suit.
Method
•
Ensure that the gas taps are in the 'OFF' position
•
Isolate the hob from the electricity supply
•
Remove all pan supports, burner caps, rings, crowns
and control knobs.
•
With the aid of a 7mm box spanner the burner
injectors can then be unscrewed and replaced by the
appropriate LPG injectors.
TO ADJUST THE GAS RATE
With the aid of a thin bladed screwdriver completely
tighten down the by pass adjustment screw, which is
located down the centre of the gas tap control shaft.
Upon completion stick the replacement rating plate
on the under side of the hob.
IMPORTANT
The replacement/conversion of the gas hob should
only be undertaken by a competent person
- KCGV1200 (5 pages)
- U31302 ZWF 16581 (36 pages)
- ZCG7551 (44 pages)
- ZKF641H (16 pages)
- KCEFE8002 (6 pages)
- ZBG 501 W (8 pages)
- SCFE700 (2 pages)
- NCFG1210C (3 pages)
- ZGA 75 B (22 pages)
- KCGV800 (5 pages)
- ZGF982C (16 pages)
- GAS HOB (16 pages)
- ZKG6020 (40 pages)
- ZCG 611 (24 pages)
- 200157 (3 pages)
- 200109 (2 pages)
- ZHQ 575 (60 pages)
- ZCM 5200 (18 pages)
- ZEA 85 (16 pages)
- ZCM ID (56 pages)
- U30356 ZKC6010 (32 pages)
- ZCM 650 ZCM 651 (36 pages)
- ZCM 631 (24 pages)
- ZKT 651 D (28 pages)
- 200144 (3 pages)
- ZDM 869 (31 pages)
- ZKT 641 H (28 pages)
- ZDF 290 (36 pages)
- ZCM 531 GB (28 pages)
- ZBE 602 (13 pages)
- 178025 (2 pages)
- ZKG5020 (36 pages)
- NCFGE8002 (3 pages)
- ZCM 611 (24 pages)
- ZKC6020 (40 pages)
- ZCM900X (28 pages)
- Professional SCFGG 700 (2 pages)
- NCFG1211 (3 pages)
- 285743 (2 pages)
- ZCG7550 (56 pages)
- ZGG 782 (20 pages)
- ZGF 982 (20 pages)
- ZCM930X (32 pages)
- Range Cookers (9 pages)
- ZKL64 X (20 pages)