beautypg.com

Electrical connection – Zanussi ZWH 7162 J User Manual

Page 23

background image

Warning! The appliance should NOT be placed on

deep pile carpeting.

Note!

Please ensure that when the appliance is installed it is

easily accessible for the engineer in the event of a

breakdown.

In the interest of the environment

The appliance should be connected to the FOUL drainage

system, the water will then be taken to a sewage works for

treatment before being discharged safely into a river.

It is essential that these appliances are not connected to

the surface water drainage system as this water is dis-

charged directly into a river or stream and may cause pol-

lution.

If you require any further advice please contact your local

water authority.

SHOWER

WASHING

MACHINE

DISHWASHER

BATH

SINK TOILET

BIDET

RAINWATER

‘RUN-OFF’

SURFACE WATER

DRAINS & SEWERS

UNTREATED

DISCHARGE

RIVER

RIVER

TREATED DISCHARGE

FOUL DRAIN

FOUL SEWERS

SEWAGE TREATMENT

WORKS

Electrical connection

Any electrical work required to install this appliance

should be carried out by a qualified electrician or compe-

tent person.

Warning! THIS APPLIANCE MUST BE EARTHED.

The manufacturer declines any liability should this

safety measure not be observed.

Before switching on, make sure the electricity supply

voltage is the same as that indicated on the appliance’s

rating plate.

Warning! Information on the electrical connection is

given on the rating plate on the inner edge of the

appliance door.

The appliance is supplied with a 13 amp plug fitted.

In the event of having to change the fuse in the plug sup-

plied, a 13 amp ASTA approved (BS1363/A) fuse must be

used.

Should the plug need to be replaced for any reason, pro-

ceed as described below.

The wires in the mains lead are coloured in accordance

with the following code:

1

2

3

4

1

Green & Yellow

2

Brown

3

Cord clamp

4

Blue

The wire coloured green and yellow must be connected to

the terminal marked with the letter «E» or by the earth
symbol or coloured green and yellow.

The wire coloured blue must be connected to the terminal

«N» or coloured black.

The wire coloured brown must be connected to the termi-

nal marked «L» or coloured red.

Upon completion there must be no cut, or stray strands of

wire present and the cord clamp must be secure over the

outer sheath.

Warning! A cut off plug inserted into a 13 amp

socket is a serious safety (shock) hazard.

Ensure that the cut off plug is disposed of safely. Should

the appliance power supply cable need to be replaced, this

must be carried out by our Service Force Centre. The

appliance should not be connected to the electrical supply

by means of an extension cable.
Note!

When the appliance is installed the power supply cable

must be accessible.

Permanent connection

In the case of permanent connection it is necessary that

you install a double pole switch between the appliance

and the electricity supply (mains), with a minimum gap of

3 mm between the switch contacts and of a type suitable

for the required load in compliance with the current elec-

trical regulations.

The switch must not break the yellow and green earth ca-

ble at any point.

23