Zanussi ZWH 7162 J User Manual
Page 21
Unscrew the three bolts.
Slide out the relevant plas-
tic spacers.
Open the porthole and re-
move the polystyrene
block fitted on the door
seal.
Fill the smaller upper hole
and the two large ones
with the corresponding
plastic plug caps supplied
in the bag containing the
instruction booklet.
Positioning
Install the machine on a flat hard floor. Make sure that air
circulation around the machine is not impeded by carpets,
rugs etc. Check that the machine does not touch the wall
or other kitchen units. Level the washing machine by rais-
ing or lowering the feet. The feet may be tight to adjust as
they incorporate a self locking nut, but the machine MUST
be level and stable.
Any necessary adjustment can be made with a spanner.
Accurate levelling prevents vibration, noise and displace-
ment of the machine during operation. Never place card-
board, wood or similar materials under the machine to
compensate for any unevenness in the floor.
If necessary, check the
setting with a spirit level.
Water inlet
Warning! This appliance must be connected to a
cold water supply
Caution! Before connecting up the appliance to new
pipework or to pipework that has not been used for
some time, run off a reasonable amount of water to flush
out any debris that may have collected
Caution! Do not use the hose from your previous
appliance to connect to water supply.
The inlet hose is screwed to the back of the appliance.
Connect the hose to a tap
with a 3/4” thread. Always
use the hose supplied with
the appliance.
35°
45°
The other end of the inlet hose which connects to the
appliance can be turned as showed in the picture.
Do not place the inlet hose downwards. Angle the hose
to the left or right depending on the position of your
water tap. Set the hose correctly by loosening the ring
nut. After positioning the inlet hose, be sure to tighten
the ring nut again to prevent leaks.
Caution! The inlet hose must not be lengthened. If it
is too short and you do not wish to move the tap,
you will have to purchase a new, longer hose specially
designed for this type of use.
21