beautypg.com

Zanussi ZDE 47100W User Manual

Page 13

background image

longer drying times and higher energy consumption. If

the hose is completely squashed, the safety cut-outs with

which the machine is fitted may operate. When operating

the tumble dryer, the room temperature must not be lower

than +5°C and higher than +35°C, as it may affect the

performance of the appliance.

Electrical connection

Details on mains voltage, type of current and the fuses

required should be taken from the rating plate. The rating

plate is fitted near the loading aperture (see “Product de-

scription” chapter).

Connect the machine to an earthed socket, in accordance

with current wiring regulations.

Warning! The manufacturer declines any

responsibility for damage or injury through failure

to comply with the above safety precautions.

Should the appliance power supply cable need to be

replaced, this must be carried out by our Service Centre.
The appliance is supplied with a 13 amp plug fitted. In the

event of having to change the fuse in the plug supplied,

a 13 amp ASTA approved BS 1363/A fuse must be used.

The wires in the mains lead are coloured in accordance

with the following code:

1

Blue - Neutral

2

cord clamp

3

Brown - Live

4

Green and Yellow - Earth

1

2

3

4

The wire coloured green and yellow must be connected

to the terminal marked with the letter «E» or by the earth
symbol or coloured green and yellow.

The wire coloured blue must be connected to the terminal

«N» or coloured black.

The wire coloured brown must be connected to the ter-

minal marked «L» or coloured red.

Upon completion there must be no cut, or stray strands

of wire present and the cord clamp must be secure over

the outer sheath.

Warning! A cut off plug inserted into a 13 amp

socket is a serious safety (shock) hazard.

Ensure that the cut off plug is disposed of safely.

Warning! The plug must be accessible after

installing the machine.

Permanent connection
In the case of permanent connection it is necessary that

you install a double pole switch between the appliance

and the electricity supply (mains), with a minimum gap

of 3 mm between the switch contacts and of a type suitable

for the required load in compliance with the current elec-

trical regulations.

The switch must not break the yellow and green earth

cable at any point.

Door reversal

To make it easier to load or unload the laundry, the door

can be reversed. The door must only be reversed by an

authorised service engineer. Please contact your local

Service Force Centre. The engineer will carry out the door

reversal at your cost.

Special accessories

Stacking kit

A special stacking kit is

available through your deal-

er, to enable the mounting of

the dyer on top of a front

loading washing machine

with cover’s depth between

48 and 60 cm. Read carefully

the instructions supplied

with the kit.

13