York PV9 User Manual
Page 2
036-21584-001 Rev. B (1004)
2
Unitary Products Group
Three elbows (two in vent pipe and one in the air intake pipe) are already accounted for and need not be included in the elbow count from the Table
above.
30-7/8
21-1/2
13-7/8
7
11
7/8
23-3/4
7/8
30-1/8
26-1/2
24-5/8
A
40
26-1/2
25-3/8
28-3/8
21-1/2
11
8
26-3/4
1-3/8
1-1/4
C
24-3/8
20
5/8
5/8
B
26-1/2
1-3/4
D
1-1/2” GAS
PIPE ENTRY
7/8” JUNCTION
BOX HOLE
T-STAT WIRING
7/8” K.O.
CONDENSATE
DRAIN 7/8” K.O.
OPTIONAL RETURN AIR
CUT-OUT (either side)
FOR USE WITH
EXTERNAL FILTER
FRAME
LEFT SIDE
FRONT
RIGHT SIDE
BOTTOM IMAGE
RETURN END
TOP IMAGE
SUPPLY END
1-1/2” GAS
PIPE ENTRY
7/8” JUNCTION
BOX HOLE
T-STAT WIRING
7/8” K.O.
CONDENSATE
DRAIN 7/8” K.O.
DIMENSIONS
Models
CFM
Cabinet
Size
Cabinet Dimension
Air Intake
A (in.)
B (in.)
C (in.)
D (in.)
PV9A12N040UP11
1200
A
14-1/2
13-1/2
12-1/8
6-1/4
PV9B12N060UP11
1200
B
17-1/2
16-1/4
15-1/8
8-1/2
PV9B12N080UP11
1200
B
17-1/2
16-1/4
15-1/8
8-1/2
PV9C16N080UP11
1600
C
21
19-3/4
18-1/2
8-7/8
PV9C20N100UP11
2000
C
21
19-3/4
18-1/2
8-7/8
PV9D20N120UP11
2000
D
24-1/2
23-1/4
21-7/8
10-5/8
COMBUSTION AIR SUPPLY AND VENT PIPING
MAXIMUM ELBOWS AND VENT LENGTHS
Models
Pipe Size
Inches (cm)
Maximum Number of Elbows*
Minimum
Length
1 2 3 4 5 6 7 8
40,000
1-1/2
30
25
20
10
N/A
N/A
N/A
N/A
5
40,000
2
70
65
60
55
50
45
35
25
5
60,000
1-1/2
(3.8) 30 25 20 10 N/A
N/A
N/A
N/A
5
60,000
2
(5.1)
60 55 50 45 40 30 20 10
5
60,000
3
(7.6)
85 80 75 70 65 60 50 40
20
80,000
1-1/2
(3.8)
20 15 N/A N/A N/A N/A N/A N/A
5
80,000
2
(5.1)
60 55 50 45 40 30 20 10
5
80,000
3
(7.6)
85 80 75 70 65 60 50 40
20
100,000
2
(5.1)
25 20 15 N/A N/A N/A N/A N/A
5
100,000
3
(7.6)
85 80 75 70 65 60 50 40
20
120,000
3
(7.6)
75 70 65 60 55 45 35 25
5