beautypg.com

York PV9 User Manual

Page 2

background image

036-21584-001 Rev. B (1004)

2

Unitary Products Group

Three elbows (two in vent pipe and one in the air intake pipe) are already accounted for and need not be included in the elbow count from the Table
above.

30-7/8

21-1/2

13-7/8

7

11

7/8

23-3/4

7/8

30-1/8

26-1/2

24-5/8

A

40

26-1/2

25-3/8

28-3/8

21-1/2

11

8

26-3/4

1-3/8

1-1/4

C

24-3/8

20

5/8

5/8

B

26-1/2

1-3/4

D

1-1/2” GAS
PIPE ENTRY

7/8” JUNCTION
BOX HOLE

T-STAT WIRING
7/8” K.O.

CONDENSATE
DRAIN 7/8” K.O.

OPTIONAL RETURN AIR
CUT-OUT (either side)
FOR USE WITH
EXTERNAL FILTER
FRAME

LEFT SIDE

FRONT

RIGHT SIDE

BOTTOM IMAGE

RETURN END

TOP IMAGE

SUPPLY END

1-1/2” GAS
PIPE ENTRY

7/8” JUNCTION
BOX HOLE

T-STAT WIRING
7/8” K.O.

CONDENSATE
DRAIN 7/8” K.O.

DIMENSIONS

Models

CFM

Cabinet

Size

Cabinet Dimension

Air Intake

A (in.)

B (in.)

C (in.)

D (in.)

PV9A12N040UP11

1200

A

14-1/2

13-1/2

12-1/8

6-1/4

PV9B12N060UP11

1200

B

17-1/2

16-1/4

15-1/8

8-1/2

PV9B12N080UP11

1200

B

17-1/2

16-1/4

15-1/8

8-1/2

PV9C16N080UP11

1600

C

21

19-3/4

18-1/2

8-7/8

PV9C20N100UP11

2000

C

21

19-3/4

18-1/2

8-7/8

PV9D20N120UP11

2000

D

24-1/2

23-1/4

21-7/8

10-5/8

COMBUSTION AIR SUPPLY AND VENT PIPING

MAXIMUM ELBOWS AND VENT LENGTHS

Models

Pipe Size

Inches (cm)

Maximum Number of Elbows*

Minimum

Length

1 2 3 4 5 6 7 8

40,000

1-1/2

30

25

20

10

N/A

N/A

N/A

N/A

5

40,000

2

70

65

60

55

50

45

35

25

5

60,000

1-1/2

(3.8) 30 25 20 10 N/A

N/A

N/A

N/A

5

60,000

2

(5.1)

60 55 50 45 40 30 20 10

5

60,000

3

(7.6)

85 80 75 70 65 60 50 40

20

80,000

1-1/2

(3.8)

20 15 N/A N/A N/A N/A N/A N/A

5

80,000

2

(5.1)

60 55 50 45 40 30 20 10

5

80,000

3

(7.6)

85 80 75 70 65 60 50 40

20

100,000

2

(5.1)

25 20 15 N/A N/A N/A N/A N/A

5

100,000

3

(7.6)

85 80 75 70 65 60 50 40

20

120,000

3

(7.6)

75 70 65 60 55 45 35 25

5