beautypg.com

Mono operation 17 – Yamaha P-2200 User Manual

Page 38

background image

Fig. 62D - 1 1 0 V AC Outlets with Lifted Neutral. Outlets will

operate with voltage varying from 0 to 220V AC creating shock

hazard and causing possible equipment damage.

220V AC on 1 1 0 V AC Outlet

It is possible (albeit, illegal and dangerous) for a

220V AC circuit to be connected to a 1 1 0 V AC outlet
as shown in Figure 62E. Fortunately, this rarely occurs.

In an older building, it may have been done to allow
1 1 0 V AC wiring to carry the 220V AC voltage needed

to run lighting equipment. If the P-2200, or some other
audio device, is plugged into such an outlet, the AC line
fuses will blow almost immediately, but some equipment
may still be damaged. In addition, this type of outlet

poses a shock hazard.

Fig. 62E - 1 1 0 V AC Outlet with a 220V AC Circuit

connected to it. This is a highly dangerous and illegal connection.

1 1 0 V AC Outlet Connected to Dimmer Circuit

Possibly more common than the 220V-wired 1 1 0 V

outlet is the connection of a 1 1 0 V AC stage outlet to a
lighting dimmer circuit. This may have been done to
allow lighting to be controlled on stage from a remote
location. An outlet connected to a dimmer is a poor, if
not illegal, practice and the light dimmer can decrease
the voltage in the circuit. Some dimmers are capable of
raising the AC voltage. In either case, audio equipment
connected to the circuit may suffer damage, and shock
hazards are also possible.

Fig. 62F - 1 1 0 V AC Outlet connected to a Light Dimmer

Circuit, a dangerous and illegal connection.

The best way to avoid all kinds of AC mains pro-

blems, for permanent or portable systems, is to check
the voltage and polarity of the outlet yourself - before
plugging in any audio equipment. Three wire AC circuit
testers are available at most hardware and electrical
stores, and will allow easy polarity and ground
continuity checking of all outlets. While these testers
may show that an outlet has an extreme over-voltage
condition (the tester may burn out), the tester may not
show less extreme, but still serious, over-voltage condi-
tions. Also, even though such testers may display
continuity to ground at the third pin of the AC outlet,
the resistance in the ground may still be high enough to
warrant the use of a separate earth ground. Thus, it is
also a good idea to carry a small voltmeter for verifying
the actual voltage at an AC outlet, and to establish a
direct path to earth ground that does not rely on the

AC mains. Some commercially available AC plug
strips have an AC voltmeter built in, or you can install
a panel mount meter that reads voltage before equip-
ment is connected to the AC circuits in an equipment
rack.

Even if the voltage and polarity of the AC outlet are

correct, the line may be "soft," that is, it may not be
capable of sustaining proper voltage under load. Monitor
the AC line voltage when the P-2200 is operating near
full power. If the AC line voltage falls below the
minimum rated for the P-2200 (105 volts RMS), the

P-2200 will not operate properly, and could conceivably
sustain damage.

Lifting the AC ground to an audio device, while it

may solve some noise problems, also lifts the safety
feature for which the AC ground was originally
designed. If you must lift the AC ground, be certain
that the AC ground is carried through to that piece of
equipment via the shield of a signal cable, or by some

other means.

Other Safety Considerations

While it may seem obvious, the P-2200 does weigh

44 Ibs (20kg), and should be adequately mounted to
prevent it from falling onto other equipment or people.
Also, while less obvious, the speaker output terminals
of the P-2200 can deliver as high as 57 volts RMS,
and
under certain conditions, this could present a shock
hazard. It is common practice in the audio industry to

use "male" connectors to carry output signals, and
"female" connectors for inputs. For speaker level

signals, however, it may be safer to reverse this con-
vention, or to use "recessed male" type connectors as
outputs to avoid the possibility of coming into contact
with the high voltage output of the P-2200.

MONO OPERATION

Connections

Connect a mono input signal, such as a single output

from a mixer or other source, through a splitter trans-
former to both of the P-2200's inputs as shown in

Figure 63A. Switch the POLARITY SWITCH on one

channel opposite that of the switch on the other channel

(one switch grounds pin 2 to pin 1 ; the other switch

grounds pin 3 to pin 1 ) .

This connection provides equal signals to each of the

P-2200's inputs with one input out of phase with the
other (reversed in polarity).

Connect the speaker load to the two red terminals

(+) on the P-2200's outputs as shown in Figure 63B.
Do not connect either speaker wire to ground as this

would short out one channel of the P-2200, and would
severely cut the power available to the speaker load.