beautypg.com

Installation instructions – Zanussi ZUQ 875 User Manual

Page 41

background image

41

INSTALLATION INSTRUCTIONS

WARNINGS:

This appliance must be installed by a qualified

electrician/competent person. Safety may be

impaired if installation is not carried out in

accordance with these instructions.

This appliance must be earthed.

Do not remove the screws from the earth tab

extending from the oven mains terminal block (Fig. 1).

Before connecting the appliance make sure that the

voltage of your electricity supply is the same as that

indicated on the rating plate. This is situated on the

lower front frame of the appliance and can be seen

upon opening the door. Alternatively the rating plate

may also be

found on the back or top of some

models (where applicable).

Do not alter the electrical circuitry of this appliance.

CHOICE OF ELECTRICAL CONNECTION

The appliance should be operated using at least

6mm

2

twin core and earth PVC insulated multicore

cable. Please choose from the most appropriate after

reading the different methods:

By connecting the appliance to a cooker point having

a double pole isolating switch providing at least 3mm

contact separation in all poles and protected with a

fuse or miniature circuit breaker at your mains fuse

box.

If you wish to connect an oven and a hob to a cooker

point you can. Oven and hob units should be

separately connected to a cooker point. See

Fig. 2.

NOTE:

It is good practice to :

Fit an Earth Leakage Circuit Breaker to your house

wiring.

Wire your appliance to the latest IEE regulations.

THINGS TO NOTE

This appliance is designed to be fitted between

cabinets with the recommended dimensions as

shown Fig. 3 & 4.

If there is an existing housing unit it must be removed.

The dimensions given provide adequate air circulation

around the unit within the cabinet, ensuring

compliance with BS EN60-335.

Fig. 2

Fig.1

Fig. 4

Fig. 3