Monitor/remote pin layout, Xh200 – Yamaha XH200 User Manual
Page 13
14
XM4180/XM4080/XH200 Owner’s Manual
● XH200
* These specifications apply to rated power supplies of 120V, 230V and 240V.
0 dBu=0.775 Vrms, Half Power=1/2 Output Power (3 dB below rated power)
Specifications and descriptions in this owner’s manual are for information pur-
poses only.
Yamaha Corp. reserves the right to change or modify products or specifica-
tions at any time without prior notice. Since specifications, equipment or
options may not be the same in every locale, please check with your Yamaha
dealer.
European models
Purchaser/User Information specified in EN55103-1 and EN55103-2.
Inrush Current: 25A
Conforms to Environments: E1, E2, E3 and E4
■
MONITOR/REMOTE PIN layout
Output Power*
40 Hz–20 kHz
THD+N= 0.1 %
70 V, RL=25
Ω
MIN
200 W x 2
100 V, RL=50
Ω
200 W x 2
Power Consumption
Standby
5 W
Idle
40 W
1/8 (4
Ω/Pink noise)
400 W
THD+N
40 Hz–20 kHz, Half Power
MAX
0.1 %
Intermodulation Distortion
60 Hz:7 kHz, 4:1, Half Power
MAX
0.1 %
Frequency Response
Po=1 W, HPF=40 Hz,
80 Hz–20 kHz
MAX
0 dB
TYP
0 dB
MIN
-0.5 dB
SN Ratio
(DIN AUDIO)
MIN
103 dB
Channel Separation
Half Power, 1 kHz, Att. max, input 600
Ω shunt
MIN
60 dB
Residual Noise
Att. min, (DIN AUDIO)
MAX
-65 dBu
Input Sensitivity
Att. max
TYP
+4 dBu
Voltage Gain
Att. max
TYP
38 dB (100 V), 35 dB (70 V)
Maximum Input Voltage
MIN
+22 dBu
Input Impedance
TYP
20 k
Ω (balanced), 10 kΩ (unbalanced)
Controls
Front Panel
POWER switch (push on/push off)
attenuator (31 position) x 2
Rear Panel
OUTPUT VOLTAGE switch (100 V/70 V) x 1
HPF switch (40 Hz/80 Hz 12 dB/oct) x 2
Connectors
INPUT
Euroblock connector (balanced) /ch
SPEAKERS
Barrier strip/ch
MONITOR/REMOTE
Dsub 15P x 1
Indicators
POWER/STANDBY
x 1 (Green/Orange)
SIGNAL
x 2 (Green)
CLIP/LIMIT
x 2 (Red)
PROTECT/MUTE
x 1 (Red)
Load Protection
POWER switch on/off mute
DC-fault: output relay off/restored automatically.
Clip limiting : THD
≥ 0.5 %
Amplifier Protection
Thermal: Cuts the output (when heatsink temp.
≥ 90 °C);
operation restored automatically.
VI limiter (RL
≤ 16
Ω
): Limits the output.
Power Supply Protection
Thermal: Power supply shutdown (when temp.
≥ 90 °C);
operation not restored automatically.
Cooling
Variable-speed fan x 1
Dimensions (W x H x D)
480 x 88 x 412 mm
Weight
9.8 kg
Included Accessories
Power cord, Security cover, Owner’s Manual,
3-pin Euroblock connector x 2
Pin No.
Signal
Description
1
GND
2
REMOTE CONTROL
STANDBY
STANDBY Control: Supply 5 VDC, 5 mADC
3
MONITOR
MODEL ID
XM4180: 560
Ω, XM4080: 680 Ω, XH200: 820 Ω (Impedance to GND)
4
REMOTE CONTROL
MUTE CH D
MUTE Control: Connect to GND, +5 V, 1 mA
5
MUTE CH C
6
MUTE CH B
7
MUTE CH A
8
MONITOR
PROTECT STATUS CH D
PROTECTION Off/ Output On: +5 VDC, Zo=270
Ω
PROTECTION On/ Output Off: 0 VDC, Zo=High
9
PROTECT STATUS CH C
10
PROTECT STATUS CH B
11
PROTECT STATUS CH A
12
OUTPUT LEVEL CH D
XM4180, XM4080
+4dBu (-27.2 dB of Speaker Output Level) at 100 W/8
Ω, RL=7.5 kΩ, Zo=300 Ω
XH200
-33.2 dB of Speaker Output Level, RL=7.5 k
Ω, Zo=300 Ω
13
OUTPUT LEVEL CH C
14
OUTPUT LEVEL CH B
15
OUTPUT LEVEL CH A
42