Xw connection kit for inv2 – Xantrex Technology XW4024-120/240-60 User Manual
Page 21
System Components and Accessories
975-0239-01-01
1–5
XW Connection Kit for INV2
The XW Connection Kit for Inv2 (FGA # 865-1020) is the extension kit required for
connecting a second or third XW Inverter/Charger in the same system.
Figure 1-5 XW Connection Kit for INV2
XW Conduit Box
XW Connection Kit includes:
•
XW Conduit Box with raceway barriers and cable strap
connections points,
•
3x 60 A, 120/240 Vac, 2-pole, Square-D, Type QOU, Din-Rail
mountable, AC breakers (includes bypass plate)
•
#6 AWG AC wiring to connect the inverter to the AC breakers
(includes 4 conduit bushings)
•
4x Power Distribution Bars (replaces factory-installed bars)
•
1x GJ250A 160 Vdc, 3/8" stud DC breaker
•
1x Bus Bar for DC positive
•
1 pair #4/0 AWG battery cables
•
AC Sync and Xanbus cables (not shown)
Power Distribution Bars
AC Bypass Plate
60A, 120/240Vac AC
Breakers
15/16" bushing for AC sync
and Xanbus knockouts
1-3/8" bushings for AC
Wiring knockouts
DC Positive Bus Bar
GJ250A DC breaker
#6 AWG AC Wiring
#4/0 AWG battery cables