Configuration – York SMS Bridge User Manual
Page 10
User Manual
Configuration
YORK Marine, Controls
Revision 1.3 · Updated: 070507
Author: Marc Anderson · Owner: RS
Project : SMS Bridge
Page 10 of 15
File: e:\york\sms bridge\manual\smsbridge-manual_13.doc
Configuration,
Continued
SMS Handler configuration (continued)
Step Action
4
COM port: Enter the number of the COM port to which the GSM modem
is connected.
If using a USB to Serial Port adaptor, to find the port number right-click
My Computer, click Manage, click Device Manager, and double-click
Ports (COM & LPT) in the list of devices. The port number should be
shown in parenthesis after the device name.
5
Baud rate: Select 115200.
6
SMS service center: Enter the phone number of the SMS service center
of your GSM provider.
7
Receive status reports: When selected, the SMS handler handles
status reports when sending SMS messages. Status reports are not
displayed.
8
GSM char set: Select GSM.
9 Click
Save configuration to save the changes.
10 Click
Start service to initialize the modem. After a few moments, the
modem’s LED starts to blink to indicate the modem has successfully
logged on to the GSM network.