beautypg.com

Zenith Z42PX21D User Manual

Page 45

background image

Owner’s Manual 45

206-4022

External Control Device Setup

Set ID

Set ID

Use this function to specify a monitor ID number.
Refer to ‘Real Data Mapping’. See page 46.

• Baud rate : 9600 bps (UART)
• Data length : 8 bits
• Parity : None

* Use a crossed (reverse) cable.

• Stop bit : 1 bit
• Communication code : ASCII code

Communication Parameters

Communication Parameters

1. Press the MENU button and then use

D / E

button to select the

SETUP

menu.

2. Press the

G

button and then use

D / E

button to select

SET ID

.

3. Press the

G

button and then use

D / E

button to adjust

SET ID

to choose the

desired monitor ID number. The adjustment range of

SET ID

is 1 ~ 99.

4. Press EXIT button to return to TV viewing or press MENU button to return to the

previous menu.

Transmission

* [Command 1]: First command to control the set.(j,k,m or x)
* [Command 2]: Second command to control the set.
* [Set ID]: You can adjust the set ID to choose desired monitor

ID number in Setup menu. Adjustment range is 1
~ 99. When selecting Set ID ‘0’, every connected
the TV is controlled. Set ID is indicated as decimal
(1~99) on menu and as Hexa decimal (0x0~0x63)
on transmission/receiving protocol.

* [DATA]: To transmit command data.

Transmit ‘FF’ data to read status of command.

* [Cr]: Carriage Return

ASCII code ‘0x0D’

* [ ]: ASCII code ‘space (0x20)’

[Command1][Command2][ ][Set ID][ ][Data][Cr]

T

T

ransmission / Receiving Protocol

ransmission / Receiving Protocol

OK Acknowledgement

* The Monitor transmits ACK (acknowledgement) based on

this format when receiving normal data. At this time, if the
data is data read mode, it indicates present status data. If
the data is data write mode, it returns the data of the PC
computer.

[Command2][ ][Set ID][ ][OK][Data][x]

Error Acknowledgement

* The Monitor transmits ACK (acknowledgement) based on

this format when receiving abnormal data from non-viable
functions or communication errors.

[Command2][ ][Set ID][ ][NG][Data][x]

Data 1: Illegal Code

2: Not supported function
3: Wait more time

01. Power

k

a

0 ~ 1

02. Input Select

k

b

0 ~ 8

03. Aspect Ratio

k

c

*

04. Screen Mute

k

d

0 ~ 1

05. Volume Mute

k

e

0 ~ 2

06. Volume Control

k

f

0 ~ 64

07. Contrast

k

g

0 ~ 64

08. Brightness

k

h

0 ~ 64

09. Color

k

i

0 ~ 64

10. Tint

k

j

0 ~ 64

11. Sharpness

k

k

0 ~ 64

12. OSD Select

k

l

0 ~ 1

13. Remote Control Lock Mode k

m

0 ~ 1

14. Treble

k

r

0 ~ 64

15. Bass

k

s

0 ~ 64

16. Balance

k

t

0 ~ 64

17. Color Temperature

k

u

0 ~ 2

18. ISM Method

j

p

*

19. Low Power

j

q

0 ~ 1

20. Orbiter Time Setting

j

r

1 ~ FE

21. Orbiter Pixel Setting

j

s

1 ~3

COMMAND 1 COMMAND 2

DATA

(Hexadecimal)

Command Reference List

Command Reference List

22. Channel Tuning

m

a

physical/program high

major/program low

major low minor high minor low attribute

23. Channel Add/Del

m

b 00 ~ 01

24. Key

m

c

key code

25. Input Select x b

*

COM-
MAND 2

COM-
MAND 1

DATA 0

(Hexadecimal)

DATA 1

(Hexadecimal)

DATA 2

(Hexadecimal)

DATA 3

(Hexadecimal)

DATA 4

(Hexadecimal)

DATA 5

(Hexadecimal)

This manual is related to the following products: