beautypg.com

Routine maintenance for sealed vrla batteries, Sealed vrla batteries – Yuasa Battery YUMICRON YUA00ACC05 User Manual

Page 35

background image

33

Batteries with voltage below 11.5v may require special
equipment and procedures to recharge.

In charging an overdischarged battery having a terminal
voltage of 11.5v or lower, its internal resistance may be
too high to charge at a normal charge voltage.
Therefore, it may be necessary to raise the voltage of
the battery initially (25v as a maximum), and charge

for approximately 5 minutes. If the ammeter shows
no change in current after 5 minutes, you need a new
battery.

Current flowing into the battery at high voltage can
become excessive. Monitor amperage and adjust voltage
as necessary to keep current at the battery’s standard
amp rating. Charge for approximately 20 hours.

Charging Instructions for Sealed VRLA Batteries
with Voltage of 11.5 or Less

How to determine battery condition

after boost charge.

Determine the condition of a sealed VRLA battery at
least 1 - 2 hours after the charge by measuring the
terminal voltage according to the table below.

Criteria

Judgement

12.8v or higher

Good

12.0 -12.8v or lower

Charge insufficient

→ Recharge

12.0v or lower

Unserviceable

→ Replace

Adjust voltage so that current will be at
standard amps after 5 minutes.

Check voltage periodically using a
voltmeter.

Recommended every 3 months from date of activation,
or 3 months from date of manufacture for batteries
activated at the factory. Keep in mind, higher storage
temperatures cause faster self-discharge and require
checking more often.

If you plan to store your vehicle for an extended time,
make sure your battery is fully charged.

Fully charged should read 12.8v - 13.0v after standing
1 - 2 hours.

When a battery is in storage, check and charge it if
the voltage drops below 12.5v for YTX batteries.

Beyond that, maintenance is the same as for any battery,
except you don’t have to worry about electrolyte:

Keep the battery top free of grime.

Check cables, clamps and case for obvious damage
or loose connections.

Clean terminals and connectors as necessary.

For storage, pull battery or disconnect battery cable.

Routine Maintenance for
Sealed VRLA Batteries

5

SECTION

Sealed VRLA
Batteries