Important Safety Requirements

This appliance must be installed in accordance with the

Gas Safety (Installation and Use) Regulations (current

addition) and the I.E.E. Wiring Regulations. Detailed

recommendations are contained in the following British

Standard Codes of Practice - B.S. 6172, B.S. 5440: Part

2 and B.S. 6891: Current Editions.

Provision for Ventilation

The room containing the cooker should have an air

supply in accordance with B.S. 5440: Part 2: Current

Editions.

The following requirements for ventilation must be met.

The cooker should not be installed in a bed sitting room

with a volume of less than 20m

3

, if it is installed in a room

of volume less 5m

3

an air vent of effective area of 110cm

2

is required; if it is installed in a room of volume between

5m

3

and 10m

3

, an air vent of effective area 50cm

2

is

required, while if the volume exceeds 11m

3

no air vent is

Technical Data

Appliance Class 2 sub class 1 and Class 1
APPLIANCE CATEGORY:II 2H3+
APPLIANCE GAS SUPPLY: Natural Gas 20 mbar

Dimensions

Height

900 mm

Depth

595 mm

Width

597 mm

Oven Capacity

1.8 Cu. ft

BURNER

RAPID

SEMI-RAPID

AUXILIARY

(large)

(medium)

(small)

POSITION

MAX

MIN

MAX

MIN

MAX

MIN

NOMINAL THERMAL

POWER kW

3.0

0.65

2.0

0.45

1.0

0.33

NOMINAL FLOW

RATE m

3

/h

0.286

0.057

0.190

0.038

0.095

0.028

NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

NOMINAL THERMAL

POWER kW

2.8

0.65

2.0

0.45

1.0

0.33

NOMINAL FLOW

RATE g/h

202

43.5

144

29

72

21,5

NOZZLE REFERENCE

86

40

71

32

50

28

NATURAL

GAS

20 mbar

TYPE OF

GAS

CHARACTERISTICS

LPG GAS

28-30/37

mbar

1/100 mm

1/100 mm

VALUE =

49.92 MJ/Kg

VALUE =

37.78 MJ/m

3

Ws -

50.7 MJ/ m

3

Instructions for the Installer

Hob

Rear left burner (semi-rapid)

2.0 kW

Front left burner (rapid)

3 kW

Rear right burner (semi-rapid)

2.0 kW

Front right burner (auxiliary)

1.0 kW

Oven

Convection Heating Element

2.080 kW

Grill Element

1.880 kW

Convection Fan

30 W

Oven light

15 W

Total rating

2.125 kW

Supply voltage (50 Hz)

230-240 V

required. However, if the room has a door which opens

directly to the outside, no air vent is required even when

the volume is between 5m

3

and 11m

3

.

If there are other fuel burning appliances in the same

room, B.S. 5440: Part. 2: Current Editions should be

consulted to determine the requisite air vent

requirements.

Location

The cooker may be located in a kitchen, a kitchen/diner

or bedsitting room but not in a bathroom or shower room.

For information regarding the fitting of flexible supply

pipes, the highest temperature at the rear of this cooker

which may come into contact with the supply pipe is

70°C above ambient.

When the appliance has been installed there must be

enough space for the glass hotplate lid to open fully.