York MPADC User Manual
Page 7

RE-STARTING YOUR WATER GUARDIAN UNIT
14. Using a paper towel or cloth, dry off all connections and your drinking water
unit.
15. Ensure that all connections are tight (CAUTION: DO NOT OVER TIGHTEN
- see item #13c).
16. Before starting the flushing and start-up process, unscrew and remove the
aerator (screen) from the filtered water spout (Fig. F). Rinse out the aera-
tor to remove any debris that may have collected on the two screens inside
it. You will reconnect the aerator upon completion of the filter flushing
process (see step #24).
17. To purge all air from the unit, turn the housing upside down and then turn
on the water at your tap faucet (Fig. G).
18. With the unit upside down, push the bypass lever of the diverter to start the
flow of water through the unit (Fig. H). Allow the water to run through the
unit and filtered water spout (without the aerator) for ONE minute. Then
close the bypass lever and shut off the water at the faucet.
19. Turn the unit right side up, place it on your counter and check all connec-
tions to confirm that there are no leaks (Fig. I).
20. Turn on the water and push the bypass lever of the diverter valve to again
start the flow of water through the unit (Fig. H).
21. Allow water to run through the unit to waste for approximately 25 minutes to
fully flush the filter and charge the carbon (Fig H).
22. Push the bypass lever inward to shutoff the flow of water through the Aqua
Dome unit.
23. Shut off the water at your faucet and check for leaks.
24. Then reconnect the aerator to the filtered water spout (Fig. F).
You now can resume using your Multi-Pure Drinking Water System
for all your drinking water, cooking, and food preparation needs.
7
Fig. F
Fig. G
Fig. H
Fig. I
Fig. J
Filtered Water
Aerator
Flush
without
filtered
water
aerator
Date of Installation:________________________________________
Fecha de Instalación
Unit Model Number:_______________________________________
Tipo de Unidad
Filter Type:______________________________________________
Tipo de Filtro
Dates of Filter Change / Fechas de Cambio del Filtro