Nsf/ansi 42 - aesthetic effects – York MPADC User Manual
Page 11

N
OTES:
1. Multi-Pure Drinking Water Systems have been certified, as indicated, by NSF International for compliance to NSF/ANSI Standard Nos. 42 & 53.
2. The Multi-Pure Drinking Water Systems have been certified by the State of California Department of Health Services for the reduction of specific
contaminants listed herein.
3. Chloroform was used as a surrogate for claims of reduction of VOCs. Multi-Pure Systems tested at >99.8% actual reduction of Chloroform. Percent
reduction shown herein reflects the allowable claims for VOCs as per tables in the Standard.
4. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
5. Filter life will vary in proportion to the amount of water used and the level of impurities in the water being processed. For optimum performance, it is
essential that the filter be replaced on a regularly scheduled basis as follows: (a) annually; (b) when the unit’s rated capacity has been reached; (c)
the flow rate diminishes; (d) the filter becomes saturated with bad tastes and odors.
6. Multi-Pure’s Aqua Dome Housing is warranted for a period of 5 years. All exterior hoses and attachments to the System are warranted for one year.
Please see the Owner’s Manual for complete product guarantee and warranty information.
7. Please see the Owner’s Manual for installation instructions and operating procedures.
8.
In compliance with New York law, it is recommended that before purchasing a water treatment system, NY residents have their water supply tested
to determine their actual water treatment needs. Please compare the capabilities of the Multi-Pure unit with your actual water treatment needs.
9.
Check for compliance with state and local laws and regulations.
10. While testing was performed under standard laboratory conditions, actual performance may vary.
11. The list of substances which the treatment device reduces does not necessarily mean that these substances are present in your tap water.
Operational Specifications
MPADC
Approximate Service Capacity (5)
750 gallons
Replacement Filter Type Model No.
CBTAD
Approximate Flow Rate @ 60 psi
0.75 gpm
Maximum Water Pressure
100 psi/7.0 kg/cm2
Minimum Water Pressure
30 psi/2.1 kg/cm2
Maximum Operating Temperature
100°F/38°C
for cold water use only
Minimum Operating Temperature
32°F/0°C
Warranty on Housing
5 years
Note: This addresses the U.S. Environmental Protection Agency (EPA) Primary and Secondary Drinking Water Regulations in effect at its time of publica-
tion, they relate to Multi-Pure’s performance in conformance to the industry performance criteria. These regulations are continually being updated at the
Federal level. Accordingly, this list of MCLs will be reviewed and amended when appropriate. Please see sales brochure for list of product certifications.
11
Model Nos: MPADC
Substance
Percent
Reduction**
Influent challenge
concentration
(mg/L unless specified)
Maximum permissible
product water
concentration
(mg/L unless specified)
CHLORAMINE as Aesthetic Effect (As
Monochloramine)
>97%
3.0 mg/L +/- 10%
0.5 mg/L
CHLORINE as Aesthetic Effect
99%
2.0 Mg/L +/- 10%
> or = 50%
PARTICULATE, (Nominal Particulate Reduction, Class
I, Particles 0.5 TO <1 UM
Class I > 99%
At Least 10,000 particles/mL
> or = 85%
NSF/ANSI 42 - Aesthetic Effects
The System has been tested according to NSF/ANSI Standard 42 for the reduction of the following substances. The con-
centration of the indicated substances in water entering the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system.