Electrical Connection

The oven is designed to be connected to 230-240V (50Hz)

electricity supply.

The oven has an easily accessible terminal block which

is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

or E

-

Earth terminal

THIS OVEN MUST BE EARTHED

The cable used to connect the oven to the electrical

supply must comply to the specifications given below.

It is necessary that you install a double pole switch

between the oven and the electricity supply (mains), with

a minimum gap of 3mm between the switch contacts

and of a type suitable for the required load in compliance

with the current rules.

The switch must not break the yellow and green earth

cable at any point.

Important

After installation and connecting, the cable must be

placed so that it cannot at any point reach a temperatu-

re of more than 60°C above the ambient temperature.

Before the oven is connected, check that the main fuse

and the domestic installation can support the load; and

that the power supply is properly earthed.

The manufacturer disclaims any responsibility should

these safety measures not be carried out.

Technical Data

Dimensions of recess

Height

580 mm.

Width

560-570 mm.

Depth

550 mm.

Dimensions of the oven cavity

Height

325 mm.

Width

420 mm.

Depth

390 mm.

Oven capacity

53 litres

Heating elements rating

Oven element

1,880 W

Top element

835 W

Bottom element

1,045 W

Convection element

2,090 W

Grill element

1,830 W

Double Grill element

2,665 W

Pizza Oven Function

3,135 W

Convection Fan

30 W

Oven Light

15 W

Cooling Fan

25 W

Total Rating

3,200 W

Supply voltage (50 Hz)

230-240 V

This oven must be installed by qualified personnel

to the relevant British Standards.

The oven must be installed according to the

instructions supplied.

Installation

Connection

Min. size

Cable / flex Fuse

via

Cable/flex type

• Cooker

2.5 mm

2

PVC/PVC

20 A

Control

twin and

Circuit

earth

For Uk use only

For Europe use only

Min. size Cable/flex Cable / flex type

Fuse

2.5 mm

2

H07 RN-F, H05 RN-F, 15 A
H05 RR-F, H05 VV-F,

H05 V2V2-F (T90),