beautypg.com

Fitting the stability bracket (not supplied), Connecting to gas – Zanussi ZCM 631 User Manual

Page 21

background image

21

Fig. 3

Fitting the Stability Bracket
(Not supplied)

If the cooker has to be installed with a flexible supply

pipe, it is necessary that a stability device is fitted.

(See safety Requirements: Page 19).

If a stability bracket is to be fitted by the installer, these

instructions should be read in conjunction with the leaflet

packed with the stability bracket.

Place cooker in its intended position and level cooker.

Mark off 295 mm (11

1

/

2

") from the right hand side of the

cooker as shown, this is the centre line of the bracket

fixing.

Draw a line 100mm (4") from the front edge of the

levelling feet (see Fig. 2) and remove cooker from its

position. Mark off 580mm (23") back from this line on

the centre line of the bracket to locate the front edge of

the lower bracket.

Fix lower bracket (with two fixing holes) to the floor, then

measure height from floor level to engagement edge on

back of cooker, dimension 'A' of Fig. 2.

Assemble upper bracket to lower bracket so that

underside of bracket is dimension 'A' +3mm (1/8") above

floor level. Re-position cooker and check that top bracket

engages into cooker back to a depth of 75mm (3"), as

shown in Fig. 2.

Should the stability bracket currently installed not allow

the cooker to stand correctly, ask the installer to replace

it with the correct type.

Fig. 2

Connecting to Gas

This cooker is designed to be installed with an appliance

flexible connection. Connection is made to the RC 1/2

(1/2" B.S.P.) threaded entry pipe located just below the

hotplate level on the rear right-hand side of the cooker.

Check for gas soundness after connecting the gas

supply.

The gas bayonet connector must be fitted in the shaded

area indicated in the diagram. Take into account that it

must be possible to pull the cooker forward sufficiently.

The hose must not get caught on the stability bracket.

Note:

For certain types of gas bayonet connection used, it

may not be possible for the appliance to be pushed fully

back to the wall stops.

Important:

Flexible tubing MUST comply with BS.669 Current

Edition.

FO 2435

600

450

130

Dimensions are given in millimeters

Dimensions are given in millimeters

LEVELLING FEET

PENCIL LINE ON THE FLOOR

PLAN VIEW OF THE COOKER

580 mm.

100 mm.

300 mm.

295 mm.

WALL FACE

A

BACK OF COOKER

SIDE VIEW

OF THE COOKER

BASE OF COOKER

ENGAGEMENT EDGE FOR

STABILITY BRACKET

FO 0179