Important safety requirements, Instructions for the installer, Dimensions – Zanussi ZCM 631 User Manual
Page 19: Technical data, Oven, Provision for ventilation

19
BURNER
ULTRA-RAPID
SEMI-RAPID
AUXILIARY
(large)
(medium)
(small)
POSITION
MAX
MIN
MAX
MIN
MAX
MIN
NOMINAL THERMAL
POWER kW
3.5
1.2
2.0
0.45
1.0
0.33
NOMINAL FLOW
RATE m
3
/h
0.333
0.114
0.190
0.043
0.095
0.031
NOZZLE REFERENCE
136
Adjust.
96
Adjust.
70
Adjust.
NOMINAL THERMAL
POWER kW
3.5
1.2
2.0
0.45
1.0
0.33
NOMINAL FLOW
RATE g/h
252
86.5
144
32
72
24
NOZZLE REFERENCE
93
56
71
32
50
28
NATURAL
GAS
20
mbar
TYPE
OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37
mbar
1/100 mm
1/100 mm
VALUE
=
49.92
MJ/Kg
VALUE
=
37.78
MJ/m
3
Ws
- 50.7
MJ/
m
3
Important Safety Requirements
This appliance must be installed in accordance with the
Gas Safety (Installation and Use) Regulations (current
addition) and the I.E.E. Wiring Regulations. Detailed
recommendations are contained in the following British
Standard Codes of Practice - B.S. 6172, B.S. 5440: Part
2 and B.S. 6891: Current Editions.
Appliance Class 2 sub class 1 and Class 1
APPLIANCE CATEGORY:
II 2H3+
APPLIANCE GAS SUPPLY: Natural gas G20 20mbar
Dimensions
Height
900 mm
Depth
600 mm
Width
600 mm
Oven Capacity
1.8 Cu. ft
Hob
Rear right burner (semi-rapid)
2,000 W
Front right burner (auxiliary)
1,000 W
Rear left burner (semi-rapid)
2,000 W
Front left burner (ultra-rapid)
3,500 W
Technical Data
Instructions for the Installer
Oven
Top heating element
835 W
Bottom heating element
1,045 W
Oven element
1,880 W
Grill Element
1,830 W
Convection heating element
2,090 W
Convection fan
30 W
Oven light
15 W
Total rating
2,135 W
Supply voltage (50 Hz)
230-240 V
Provision for Ventilation
The room containing the cooker should have an air supply
in accordance with B.S. 5440: Part 2: Current Editions.
The following requirements for ventilation must be met.
The cooker should not be installed in a bed sitting room
with a volume of less than 20m
3
, if it is installed in a
room of volume less 5m
3
an air vent of effective area of
110cm
2
is required; if it is installed in a room of volume
between 5m
3
and 10m
3
, an air vent of effective area 50cm
2
is required, while if the volume exceeds 11m
3
no air vent
is required. However, if the room has a door which opens
directly to the outside, no air vent is required even when
the volume is between 5m
3
and 11m
3
.