beautypg.com

Caution, Grc 6 mv y w rh – White Rodgers 37-5086B User Manual

Page 4

background image

4

RH

Y

MV

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 7. Typical wiring diagram for heat/cool, 4-wire, single transformer systems

TRANSFORMER

6

Cooling

System

Fan

Relay

Heating

System

RC

JUMPER

WIRE

G

RC

6

MV

Y

W

RH

Thermostat Terminal Connections

G

From 24 VAC

transformer

From fan relay

From cooling system

Y

CONNECT red jumper

wire (provided)

W

RH

From heating system

NOTE

RED jumper wire (pro-
vided with thermostat)
must be connected be-
tween thermostat's RH
and RC terminals for pro-
per thermostat operation
with this system.

RC

Y

MV

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 6. Typical wiring diagram for cool only, 3-wire, single transformer systems

6

Fan

Relay

Cooling

System

RH

TRANSFORMER

G

RC

6

MV

Y

W

RH

Thermostat Terminal Connections

G

From 24 VAC

transformer

From fan relay

From cooling system

RC

Y

RH

Y

MV

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 5. Typical wiring diagram for heat only, 3-wire, single transformer systems

TRANSFORMER

6

RC

Fan

Relay

Heating

System

JUMPER

WIRE

G

RC

6

MV

Y

W

RH

W

RH

Thermostat Terminal Connections

G

From heating system

From 24 VAC

transformer

From fan relay

CONNECT red jumper

wire (provided)

NOTE

RED jumper wire (pro-
vided with thermostat)
must be connected be-
tween thermostat's RH
and RC terminals for pro-
per thermostat operation
with this system.

CAUTION

!

All wiring diagrams are for typical systems only. Refer to
equipment manufacturers’ instructions for specific sys-
tem wiring information.

To prevent electrical shock and/or equipment
damage, disconnect electrical power at the main
fuse box or circuit breaker until installation is
complete.

NOTE

RH

Y

MV

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 4. Typical wiring diagram for heat only, 2-wire, single transformer systems

TRANSFORMER

6

Heating

System

RC

G

RC

6

MV

Y

W

RH

W

RH

Thermostat Terminal Connections

From heating system

From 24 VAC transformer

This manual is related to the following products: