beautypg.com

Direct-vent natural gas heater, Troubleshooting – Williams 4003532 User Manual

Page 18

background image

18

201842

DIRECT-VENT NATURAL GAS HEATER

THE COMFORT PRODUCTS PEOPLE

OBSERVED PROBLEM

Ignition failures

Excessive noise

Main burner will not cycle off

Furnace will not operate

POSSIBLE CAUSE

5. Burner cycles off and glo bar comes on

immediately, check the following:

1. Blower out of balance
2. Motor hums

1. Thermostat setting
2. Gas valve stuck open

1. Wiring connections or shorts

REMEDY

5. A. Check flame sensing probe. Be sure

probe is positioned in the burner
flame and glowing cherry red. Check
wire and wire connections at probe
and ignition control

B. If wire and wire connections okay,

check for voltage across brown and
orange wires at ignition control. If
no voltage, replace ignition control

C. If voltage present, check wiring and

wire connections at valve

D. If wire and wire connections okay,

replace valve

1. Replace blower
2. Replace motor

1. Check thermostat
2. Check gas valve. If stuck open, replace.

Do not attempt to repair valve!

1. Check all wiring to assure proper con-

nection or detect possible shorts

TROUBLESHOOTING

Continued

This manual is related to the following products: