Mounting Guidelines
• Temperature <200°C (392°F): bond with high-temperature
epoxy adhesive
• Temperature >200°C (392°F): screw hole can be provided
(recommend insulation buffer such as mica spacer)
• Clamp using single or multiple-point fasteners
Optional Thermocouple
• Bonded bare wire Type K thermocouple with ceramic
insulation for <400°C (752°F)
• Drilled hole can be provided for installing a sheathed
thermocouple for <600°C (1112°F)
Lead Wire and Terminations
• Power terminals exit locations - extended from side on
square and rectangular shapes and from the top on the
ring shapes
• Flexible lead extension
• Teflon
®
insulated silver-plated copper lead extension
• Lead extension length - standard length 305 mm (12 in.)
How to Order
To order your standard ULTRAMIC 600 heater, please specify
Watlow code number.
If our standard units do not meet your application needs,
Watlow can rapidly manufacture the ULTRAMIC 600 to your
special requirements. For made-to-order units, please consult
the factory.
Availability
Standard heaters are available for shipment in seven business
days or less. While normally customized for the application,
these products enable a development engineer to quickly and
easily acquire a test sample to determine its suitability in the
application.
Custom configurations involving grooves, holes, product
size or surface finishes are routinely manufactured to meet
the exact requirements of the design engineer. Delivery is
dependent on complexity of order. Please consult factory.
Standard Product Ordering Information
FEN-ULT-1007
Square
❶
CER-1-01-00002
25 mm x 25 mm x 2.5 mm
967
1000
(155.04)
240
(0.98 in. x 0.98 in. x 0.1 in.)
CER-1-01-00006
50 mm x 50 mm x 2.5 mm
1938
500
(77.52)
240
(1.97 in. x 1.97 in. x 0.1 in.)
CER-1-01-00093
25 mm x 25 mm x 2.5 mm
150
150
(24)
120
(0.98 in. x 0.98 in. x 0.1 in.)
CER-1-01-00097
19 mm x 19 mm x 2.5 mm
200
357 (55.56)
120
(0.75 in. x 0.75 in. x 0.1 in.)
Rectangular
❶
CER-1-01-00001
25 mm x 15 mm x 2.5 mm
580
1000
(155.04)
120
(0.98 in. x 0.6 in. x 0.1 in.)
CER-1-01-00003
50 mm x 10 mm x 2.5 mm
582
750 (116.28)
120
(1.97 in. x 0.39 in. x 0.1 in.)
CER-1-01-00004
50 mm x 10 mm x 2.5 mm
770
1000
(155.04)
240
(1.97 in. x 0.39 in. x 0.1 in.)
CER-1-01-00005
50 mm x 25 mm x 2.5 mm
1453
750
(116.28)
240
(1.97 in. x 0.98 in. x 0.1 in.)
CER-1-01-00007
75 mm x 25 mm x 2.5 mm
1455
500
(77.52)
240
(2.95 in. x 0.98 in. x 0.1 in.)
CER-1-01-00098
25 mm x 15 mm x 2.5 mm
180
305 (48.0)
120
(0.98 in. x 0.6 in. x 0.1 in.)
CER-1-01-00105
50 mm x 25 mm x 2.5 mm
100
50
(8)
120
(1.97 in. x 0.98 in. x 0.1 in.)
Ring
❷
CER-1-02-00001
38 mm O.D./29 mm I.D.
733
1000
(155.04)
120
(1.50 in. O.D./1.14 in. I.D.)
CER-1-02-00002
77.5 mm O.D./59 mm I.D.
770
250
(38.76)
240
(3.05 in. O.D./2.32 in. I.D.)
Code
Voltage
Number
Size
Watts
W/in
2
(W/cm
2
)
VÅ(ac)
❶
Leads exit short side
❷
Leads exit top
Standard configurations include:
• Power lead wires with Teflon
®
insulation 305 mm (12 in.)
• Bonded Type K thermocouple with 305 mm (12 in.) Teflon
®
insulated lead extension
• Surface finish (Ra) <0.8 µm (32 µ-in.)
Teflon
®
is a registered trademark of E.I. du Pont Nemours & Company.
To be automatically connected to the nearest North American Technical and Sales Office call:
1-800-WATLOW2
International Technical and Sales Offices:
Australia, +61-3-9335-6449 • China, +86-21-3950-9510 • France, +33 (0) 3073-2425 •
Germany, +49 (0) 7253-9400-0 • Italy, +39 (0) 2 458-8841 • Japan, +81-3-3518-6630 • Korea, +82-2-575-9804 • Malaysia, +60-3-7980-7741 •
Mexico, +52 (442) 217-6235 • Shanghai, +86-21-3950-9504 • Singapore, +65-6773-9469 • Spain, +34 91 675 1292 • Sweden, +46 35-27-11-66 •
Taiwan, +886-7-288-5168 • United Kingdom, +44 (0) 115-964-0777