beautypg.com

Verify anti-tip bracket location, Level range – Whirlpool Drop-In Electric Range User Manual

Page 7

background image

7

4-Wire Cable from Home Power Supply

IMPORTANT: Use the 4-wire cable from home power supply
where local codes do not allow grounding through neutral, New
Branch circuit installations (1996 NEC), mobile homes,
recreational vehicles, and new construction.

1. Connect the 2 black wires (B) together using a UL listed wire

connector.

2. Connect the 2 red wires (C) together using a UL listed wire

connector.

3. Untwist white wire from green (or bare) ground wire coming

from the range.

4. Connect the 2 white wires (F) together using a UL listed wire

connector.

5. Connect the green (or bare) ground wire (H) from the range

cable to the green (or bare) ground wire (in the junction box)
using a UL listed wire connector.

6. Install junction box cover.

3-Wire Cable from Home Power Supply

IMPORTANT: Use the 3-wire cable from home power supply
where local codes permit a 3-wire connection.

1. Connect the 2 black wires (C) together using a UL listed wire

connector.

2. Connect the 2 white wires (D) and the green (or bare) ground

wire (of the range cable) using a UL listed wire connector.

3. Connect the 2 red wires (G) together using a UL listed wire

connector.

4. Install junction box cover.

Verify Anti-Tip Bracket Location

1. Making sure the anti-tip bracket is installed:

Look for the anti-tip bracket securely attached to slats
under range.

Slide range back so rear range foot is engaged with
anti-tip bracket.

Level Range

1. Place rack in oven. Place level on rack and check levelness of

range, first side to side; then front to back.

2. If range is not level, using two or more people remove range

from cutout onto cardboard or hardboard.

3. Use wrench to adjust leveling legs up or down until range is

level. Using 2 or more people, lift range back into cutout.

4. Check that rear leveling leg is engaged in anti-tip bracket.

NOTE: Range must be level for satisfactory baking conditions.

A. Cable from home power supply
B. Black wires

C. Red wires
D. 4-wire flexible conduit from

range

E. Junction box

F. White wires

G. UL listed wire connectors

H. Green (or bare) ground wires

I. UL listed or CSA approved

conduit connector

A. Cable from home power supply
B. Junction box

C. Black wires
D. White wires

E. Green (or bare) ground wire

(from range)

F. 4-wire flexible conduit from

range

G. Red wires

H. UL listed wire connectors

I. UL listed or CSA approved

conduit connector

A
B

C

D

E

F

G

H

I

B

C

D

E

F

H

G

A

I

This manual is related to the following products: